Effect of Preheating Conditions on the Mechanical Reliability of HDPE Extrusion-Welded Structures for Medical Devices
Polymers · 11.06.2026 · 18 (12) · 1467
DOI: 10.3390/polym18121467 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 11.06.2026. Verfasst von Chung-Woo Lee und 1 weiteren Autor:innen. Beteiligte Einrichtung: EM Actuators Lab, Korea Institute of Medical Microrobotics, Gwangju 61011, Republic of Korea. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Health & Welfare, Republic of Korea.
Abstract (Originalsprache)
Polymers are increasingly used as structural materials in medical devices due to their lightweight, chemical resistance, and electrical insulation properties. High-density polyethylene (HDPE) is widely applied; however, the fabrication of large or thick components often requires extrusion welding. Since joint performance directly affects structural reliability, controlling welding quality is essential. In this study, the effects of preheating conditions on the mechanical performance of HDPE extrusion-welded joints were systematically investigated. Preheating temperature and hot-air movement speed were selected as key variables, and their influence on tensile, flexural, and elongation properties was evaluated experimentally. The results provide insight into the role of preheating in weld quality and offer guidance for process optimization in medical device applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- EM Actuators Lab, Korea Institute of Medical Microrobotics, Gwangju 61011, Republic of Korea.
ORCID-Profile: Chung-Woo Lee, Eunho Choe
Förderung
- Ministry of Health & Welfare, Republic of Korea
Zitieren
APA
Lee, C. W., & Choe, E. (2026). Effect of Preheating Conditions on the Mechanical Reliability of HDPE Extrusion-Welded Structures for Medical Devices. Polymers, 18(12), 1467. https://doi.org/10.3390/polym18121467
Vancouver
Lee CW, Choe E. Effect of Preheating Conditions on the Mechanical Reliability of HDPE Extrusion-Welded Structures for Medical Devices. Polymers. 2026;18(12):1467. doi:10.3390/polym18121467
BibTeX
@article{Lee2026,
author = {Lee, Chung-Woo and Choe, Eunho},
title = {Effect of Preheating Conditions on the Mechanical Reliability of HDPE Extrusion-Welded Structures for Medical Devices},
journal = {Polymers},
year = {2026},
volume = {18},
number = {12},
pages = {1467},
doi = {10.3390/polym18121467}
}
EUVIMED