Evaluation of the Effect of Different Light-Curing Protocols on the Microhardness of Contemporary Bulk-Fill Resin Composites
Polymers · 29.10.2025 · 17 (21) · 2889
DOI: 10.3390/polym17212889 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 29.10.2025. Verfasst von Selma Jakupović und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry and Endodontics, Faculty of Dentistry with Dental Clinical Center, University of Sarajevo, 71000 Sarajevo, Bosnia…. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Federal Ministry of Education and Science, Bosnia and Herzegovina.
Abstract (Originalsprache)
Background
The study investigates newly developed composite materials with advanced filler technology and modified resin matrices, designed to enhance esthetic quality, clinical efficiency, and mechanical properties. This study evaluated the effect of two light-curing protocols—a conventional low-voltage (LV) protocol (10 s at 1200 mW/cm2) and a high-voltage (HV) protocol (3 s at 3000 mW/cm2)—on the microhardness (MH), bottom/top MH ratio, and the correlation between filler content (wt%, vol%) and MH of bulk-fill resin-based composites (RBCs). Four RBCs were tested: Tetric PlusFill (TPF), Tetric Plus Flow(TPFW), Tetric PowerFill (PFL), and Tetric PowerFlow (PFW). Materials and Methods: Samples were fabricated in the laboratory using specially designed cylindrical molds (diameter = 8 mm, height = 4 mm). Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used.
Conclusions
The MH of bulk-fill RBCs was found to be influenced by both material composition and the applied light-curing protocol. An increase in filler content resulted in higher MH values under both protocols, with the filler volume fraction exhibiting a stronger correlation than the weight fraction. While both flowable and sculptable Tetric Plus composites exhibited higher MH values under the HV protocol, Tetric Power composites demonstrated greater initial hardness under LV protocol. The flowable composite PFW showed the most pronounced reduction in MH under HV curing. The bottom/top MH ratio exceeded 80% in all tested materials, confirming adequate polymerization throughout the composite layers.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Restorative Dentistry and Endodontics, Faculty of Dentistry with Dental Clinical Center, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
- Department of Mechanical Design, Faculty of Mechanical Engineering, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
- Department of Pediatric and Preventive Dentistry, Faculty of Dentistry with Dental Clinical Center, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
- Department of Community Healthcare, Faculty of Health Studies, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
ORCID-Profile: Selma Jakupović, Nedim Pervan, Damir Duratbegović, Vedran Jakupović, Enis Muratović
Förderung
- The Federal Ministry of Education and Science, Bosnia and Herzegovina
Zitieren
APA
Jakupović, S., Pervan, N., Duratbegović, D., Jakupović, V., Muratović, E., & Kobašlija, S. (2025). Evaluation of the Effect of Different Light-Curing Protocols on the Microhardness of Contemporary Bulk-Fill Resin Composites. Polymers, 17(21), 2889. https://doi.org/10.3390/polym17212889
Vancouver
Jakupović S, Pervan N, Duratbegović D, Jakupović V, Muratović E, Kobašlija S. Evaluation of the Effect of Different Light-Curing Protocols on the Microhardness of Contemporary Bulk-Fill Resin Composites. Polymers. 2025;17(21):2889. doi:10.3390/polym17212889
BibTeX
@article{Jakupovi2025,
author = {Jakupović, Selma and Pervan, Nedim and Duratbegović, Damir and Jakupović, Vedran and Muratović, Enis and Kobašlija, Sedin},
title = {Evaluation of the Effect of Different Light-Curing Protocols on the Microhardness of Contemporary Bulk-Fill Resin Composites},
journal = {Polymers},
year = {2025},
volume = {17},
number = {21},
pages = {2889},
doi = {10.3390/polym17212889}
}
EUVIMED