Assessment of Microhardness of Conventional and Bulk-Fill Resin Composites Using Different Light-Curing Intensity
Polymers · 10.05.2023 · 15 (10) · 2250
DOI: 10.3390/polym15102250 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 10.05.2023. Verfasst von Selma Jakupović und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry and Endodontics, Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovin…. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Ministry of Science, Higher Education and Youth of the Sarajevo Canton, BiH.
Abstract (Originalsprache)
(1)
Background
This study evaluates the effect of a conventional/low-voltage light-curing protocol (LV protocol) (10 s with 1340 mW/cm2) and high-voltage light-curing protocol (HV protocol) (3 s with 3440 mW/cm2) on the microhardness (MH) of dental resin-based composites (RBCs). Five resin composites were tested: conventional Evetric (EVT), Tetric Prime (TP), Tetric Evo Flow (TEF), bulk-fill Tetric Power Fill (PFL), and Tetric Power Flow (PFW). (2) Materials and Methods: Two tested composites (PFW and PFL) were designed for high-intensity light curing. The samples were made in the laboratory in specially designed cylindrical molds; diameter = 6 mm and height = 2 or 4 mm, depending on the type of composite. Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. (3)
Conclusions
MH of RBCs is more dependent on material composition than on light-curing protocol. Filler wt% has a greater influence on MH values compared to filler vol%. The bottom/top ratio showed values over 80% for bulk composites, while for conventional sculptable composites, borderline or suboptimal values were measured for both curing protocols.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Restorative Dentistry and Endodontics, Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
- Department of Mechanical Design, Faculty of Mechanical Engineering, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
- Department of Prosthodontics, Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
- Department of Dental Morphology with Dental Anthropology and Forensics, Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
- Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
ORCID-Profile: Nedim Pervan, Elmedin Mešić, Enis Muratović
Förderung
- The Ministry of Science, Higher Education and Youth of the Sarajevo Canton, BiH
Zitieren
APA
Jakupović, S., Pervan, N., Mešić, E., Gavranović-Glamoč, A., Bajsman, A., Muratović, E., Kazazić, L., & Kantardžić-Kovačević, A. (2023). Assessment of Microhardness of Conventional and Bulk-Fill Resin Composites Using Different Light-Curing Intensity. Polymers, 15(10), 2250. https://doi.org/10.3390/polym15102250
Vancouver
Jakupović S, Pervan N, Mešić E, Gavranović-Glamoč A, Bajsman A, Muratović E, et al. Assessment of Microhardness of Conventional and Bulk-Fill Resin Composites Using Different Light-Curing Intensity. Polymers. 2023;15(10):2250. doi:10.3390/polym15102250
BibTeX
@article{Jakupovi2023,
author = {Jakupović, Selma and Pervan, Nedim and Mešić, Elmedin and Gavranović-Glamoč, Alma and Bajsman, Anita and Muratović, Enis and Kazazić, Lejla and Kantardžić-Kovačević, Alma},
title = {Assessment of Microhardness of Conventional and Bulk-Fill Resin Composites Using Different Light-Curing Intensity},
journal = {Polymers},
year = {2023},
volume = {15},
number = {10},
pages = {2250},
doi = {10.3390/polym15102250}
}
EUVIMED