Comparison of Microhardness and Depth of Cure of Six Bulk-Fill Resin Composites
Journal of Composites Science · 05.08.2025 · 9 (8) · 418
DOI: 10.3390/jcs9080418 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Composites Science, online erschienen am 05.08.2025. Verfasst von Tomislav Skrinjaric und 5 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Physicomechanical properties and clinical service of bulk-fill composites depend on their adequate polymerization and depth of cure. Some manufacturers claim that these composites can be adequately cured when used in bulks exceeding 4 mm.
Objective
The aim of this study was to compare Vickers microhardness (VMH) and depth of cure (DOC) of six contemporary bulk-fill resin composites at depths of 4 mm and 6 mm. Material and methods. Six bulk-fill composites were evaluated in this study: 1. Tetric EvoCeram Bulk (Ivoclar Vivadent, Schaan, Liechtenstein), (TEC); 2. Filtek Bulk Fill Posterior (3M ESPE Dental Products Division, St. Paul, MN, USA), (FBF); 3. Filtek One Bulk Fill (3M ESPE Dental Products Division, St. Paul, MN, USA, (FOB); 4. SonicFill 2 (Kerr, Orange, CA, USA), (SF2); 5. Admira Fusion X-tra (Voco, GmbH, Cuxhaven, Germany), (AFX); 6. GrandioSO X-tra (Voco, GmbH, Cuxhaven, Germany), (GSX). The 18 specimens (3 of each composite) were prepared in split Teflon moulds of 4 mm diameter and 6 mm thickness. All composites were cured in standard mode for 20 s using LED LCU (D-Light Duo, RF-Pharmaceuticals Sarl, Geneva, Switzerland; 1200–1300 mW/cm). The VMH was measured using a digital Micro Hardness Tester Shimadzu (HMV-2T E, Shimadzu Corporation, Kyoto, Japan). A 50 g (0.5 N) load force was applied for 30 s. Each specimen was measured at five places selected by chance at each level (N = 15). The hardness ratio or DOC was calculated for all samples as the ratio of bottom and surface microhardness at levels of 4 and 6 mm. Data were analysed using one-way ANOVA and Tukey’s post hoc test.
Results
Significant reduction in VMH was observed for all tested materials when comparing top surface and bottom (p < 0.01). The highest VMH was obtained for GSX and AFX, and the lowest for TEC. The results show that the degree of polymerization was adequate for all tested materials at a depth of 6 mm, since the hardness ratio exceeded 0.80 in all cases. The hardness ratio at 4 mm was high for all tested composites ranging from 0.91 for TEC to 0.98 for GSX. All composites showed adequate DOC at the bottom of the 6 mm bulk samples. However, the hardness ratio was the highest for Admira Fusion X-tra (0.96) and GrandioSO X-tra (0.97).
Conclusions
All tested materials showed a significant decrease in microhardness from the top surface to the bottom. The DOC was adequate for all bulk-fill composites at a depth of 6 mm cured under standard mode for 20 s. All bulk-fill resin composites evaluated in this study can be used in bulk, up to 6 mm.
Zitieren
APA
Skrinjaric, T., Gorseta, K., Bagaric, J., Sojcic, P. B., Stojanovic, J., & Marks, L. A. M. (2025). Comparison of Microhardness and Depth of Cure of Six Bulk-Fill Resin Composites. Journal of Composites Science, 9(8), 418. https://doi.org/10.3390/jcs9080418
Vancouver
Skrinjaric T, Gorseta K, Bagaric J, Sojcic PB, Stojanovic J, Marks LAM. Comparison of Microhardness and Depth of Cure of Six Bulk-Fill Resin Composites. Journal of Composites Science. 2025;9(8):418. doi:10.3390/jcs9080418
BibTeX
@article{Skrinjaric2025,
author = {Skrinjaric, Tomislav and Gorseta, Kristina and Bagaric, Jelena and Sojcic, Petra Bucevic and Stojanovic, Jakov and Marks, Luc A. M.},
title = {Comparison of Microhardness and Depth of Cure of Six Bulk-Fill Resin Composites},
journal = {Journal of Composites Science},
year = {2025},
volume = {9},
number = {8},
pages = {418},
doi = {10.3390/jcs9080418}
}
EUVIMED