Coffee Staining and Simulated Brushing Induced Color Changes and Surface Roughness of 3D-Printed Orthodontic Retainer Material

Durgesh Bangalore iD, Abdullah M Alshehri, Omar Alsadon iD, Samer M Alaqeel, Omar Alageel, Majed M Alsarani, Haitham Almansour iD, Obaid AlShahrani

Polymers · 01.05.2023 · 15 (9) · 2164

DOI: 10.3390/polym15092164 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers, online erschienen am 01.05.2023. Verfasst von Durgesh Bangalore und 7 weiteren Autor:innen. Beteiligte Einrichtung: Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh 7268, Saudi Arabia. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This in vitro study evaluated the influence of combined coffee staining and simulated brushing-induced color changes and surface roughness on 3D-printed orthodontic retainers. Specimens measuring 10 × 10 × 0.75 mm3 were obtained either by conventional vacuum forming or 3D printing at four print angulations (0°, 15°, 30°, and 45°) (n = 10). The prepared specimens were immersed in a coffee beverage and then mechanically brushed using a simulating device. The specimen’s color difference (ΔE) and surface roughness (Ra) were quantified using a spectrophotometer and a non-contact profilometer, respectively. The highest and lowest mean ΔE values were recorded for the 3D-printed-45° (4.68 ± 2.07) and conventional (2.18 ± 0.87) groups, respectively. The overall mean comparison of ΔE between the conventional and 3D-printed groups was statistically significant (p < 0.01). After simulated brushing, all groups showed a statistically significant increase in the Ra values (p < 0.01). The highest Ra was in the 3D-printed-45° (1.009 ± 0.13 µm) and conventional (0.743 ± 0.12 µm) groups, respectively. The overall ΔE of 3D-printed orthodontic retainers was not comparable to conventional VFRs. Among the different angulations used to print the retainers, 15° angulations were the most efficient in terms of color changes and surface roughness and were comparable to conventional VFRs.

Schlagwörter

Stichwörter der Autor:innen

3D printingcolororthodontic retainerstereolithographysurface roughnesstooth brushing

Autor:innen und Institutionen

  • Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh 7268, Saudi Arabia.

ORCID-Profile: Durgesh Bangalore, Omar Alsadon, Haitham Almansour

Zitieren

APA

Bangalore, D., Alshehri, A. M., Alsadon, O., Alaqeel, S. M., Alageel, O., Alsarani, M. M., Almansour, H., & AlShahrani, O. (2023). Coffee Staining and Simulated Brushing Induced Color Changes and Surface Roughness of 3D-Printed Orthodontic Retainer Material. Polymers, 15(9), 2164. https://doi.org/10.3390/polym15092164

Vancouver

Bangalore D, Alshehri AM, Alsadon O, Alaqeel SM, Alageel O, Alsarani MM, et al. Coffee Staining and Simulated Brushing Induced Color Changes and Surface Roughness of 3D-Printed Orthodontic Retainer Material. Polymers. 2023;15(9):2164. doi:10.3390/polym15092164

BibTeX
@article{Bangalore2023,
  author = {Bangalore, Durgesh and Alshehri, Abdullah M and Alsadon, Omar and Alaqeel, Samer M and Alageel, Omar and Alsarani, Majed M and Almansour, Haitham and AlShahrani, Obaid},
  title = {Coffee Staining and Simulated Brushing Induced Color Changes and Surface Roughness of 3D-Printed Orthodontic Retainer Material},
  journal = {Polymers},
  year = {2023},
  volume = {15},
  number = {9},
  pages = {2164},
  doi = {10.3390/polym15092164}
}
Kostenlos starten →