EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Crown Height Space and Abutment Configuration on the Maximum Recorded Load of Implant-Supported Monolithic Zirconia Crown Assemblies

Özay Özsoy iD, Melek Nur Ürün, Şeyda Bektaş iD, Serdar Polat iD

Materials · 03.11.2026 · 19 (21) · 4683

DOI: 10.3390/ma19214683 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 03.11.2026. Verfasst von Özay Özsoy und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gazi University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This in vitro study evaluated the effects of crown height space (CHS) and abutment configuration on maximum recorded load and described post-test damage in implant-supported monolithic zirconia crown assemblies. Sixty specimens were assigned to six groups (n = 10) combining Ti-base or multi-unit configurations with nominal CHS levels of approximately 13.5, 15.5, or 17.5 mm. After 200,000 thermomechanical aging cycles at 50 N with thermal cycling between 5 °C and 55 °C, specimens underwent eccentric vertical loading on the buccal incline of the functional cusp using a 4 mm spherical tip at 1 mm/min. The primary outcome was maximum recorded load (global peak load), not the onset of irreversible damage. Two-way ANOVA indicated a CHS effect (p = 0.012), but no significant effect of abutment configuration (p = 0.128) or interaction (p = 0.627). The CHS effect persisted in the HC3 analysis (p = 0.043). The lowest versus highest CHS comparison remained significant in heteroscedasticity-sensitive analyses; the lowest-versus-intermediate comparison depended on analytical approach. Four zirconia crown fractures occurred in the lowest-CHS Ti-base group; other post-test damage predominantly involved prosthetic connection components. Within these laboratory conditions, CHS influenced assembly-level maximum recorded load without establishing a continuous or linear relationship.

Schlagwörter

Stichwörter der Autor:innen

Ti-basecrown heightimplant-supported restorationmaximum recorded loadmonolithic zirconiamulti-unit abutmentscrew-retained restoration

Autor:innen und Institutionen

  • Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey.

ORCID-Profile: Özay Özsoy, Şeyda Bektaş, Serdar Polat

Förderung

  • Gazi University

Zitieren

APA

Özsoy, Ö., Ürün, M. N., Bektaş, Ş., & Polat, S. (2026). Effect of Crown Height Space and Abutment Configuration on the Maximum Recorded Load of Implant-Supported Monolithic Zirconia Crown Assemblies. Materials, 19(21), 4683. https://doi.org/10.3390/ma19214683

Vancouver

Özsoy Ö, Ürün MN, Bektaş Ş, Polat S. Effect of Crown Height Space and Abutment Configuration on the Maximum Recorded Load of Implant-Supported Monolithic Zirconia Crown Assemblies. Materials. 2026;19(21):4683. doi:10.3390/ma19214683

BibTeX
@article{zsoy2026,
  author = {Özsoy, Özay and Ürün, Melek Nur and Bektaş, Şeyda and Polat, Serdar},
  title = {Effect of Crown Height Space and Abutment Configuration on the Maximum Recorded Load of Implant-Supported Monolithic Zirconia Crown Assemblies},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {21},
  pages = {4683},
  doi = {10.3390/ma19214683}
}
Kostenlos starten →