Fachartikel in der Zeitschrift Clinical and Experimental Dental Research, online erschienen am 16.06.2024. Verfasst von Amirreza Hendi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, School of Dentistry, Dental Sciences Research Center, Guilan University of Medical Sciences, Rasht, Iran. Hauptthemen laut MEDLINE: Dental Restoration Failure, Dental Implant-Abutment Design, Torque, Dental Abutments. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Guilan University of Medical Sciences.
Abstract (Originalsprache)
Objectives
The stability of the abutment screw is pivotal for successful implant‐supported restorations, yet screw loosening remains a common complication, leading to compromised function and potential implant failure. This study aims to evaluate the effect of different implant‐abutment types and heights on screw loosening in cases with increased crown height space (CHS). Materials and Methods In this in vitro study, a total of 64 abutments in eight distinct groups based on their type and height were evaluated. These groups included stock, cast, and milled abutments with heights of 4 mm (groups S4, C4, and M4), 7 mm (groups S7, C7, and M7), and 10 mm (groups C10 and M10). Removal torque loss (RTL) was assessed both before and after subjecting the abutments to dynamic cyclic loading. Additionally, the differences between initial RTL and RTL following cyclic loading were analyzed for each group ( p < .05).
Results
The C10 group demonstrated the highest RTL, whereas the S4 group exhibited the lowest initial RTL percentage ( p < .05). Furthermore, the study established significant variations in RTL percentages and the discrepancies between initial and postcyclic loading RTL across different abutment groups ( p < .05). Additionally, both abutment types and heights were found to significantly influence the RTL percentage ( p < .05).
Conclusion
The type and height of the implant abutment affected screw loosening, and in an increased CHS of 12 mm, using a stock abutment with a postheight of 4 mm can be effective in minimizing screw loosening.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, School of Dentistry, Dental Sciences Research Center, Guilan University of Medical Sciences, Rasht, Iran.
- School of Dentistry, Dental Sciences Research Center, Guilan University of Medical Sciences, Rasht, Iran.
ORCID-Profile: Mehran Falahchai
Förderung
- Guilan University of Medical Sciences
Zitieren
APA
Hendi, A., Mirzaee, S., & Falahchai, M. (2024). The effect of different implant‐abutment types and heights on screw loosening in cases with increased crown height space. Clinical and Experimental Dental Research, 10(3). https://doi.org/10.1002/cre2.894
Vancouver
Hendi A, Mirzaee S, Falahchai M. The effect of different implant‐abutment types and heights on screw loosening in cases with increased crown height space. Clinical and Experimental Dental Research. 2024;10(3). doi:10.1002/cre2.894
BibTeX
@article{Hendi2024,
author = {Hendi, Amirreza and Mirzaee, Sobhan and Falahchai, Mehran},
title = {The effect of different implant‐abutment types and heights on screw loosening in cases with increased crown height space},
journal = {Clinical and Experimental Dental Research},
year = {2024},
volume = {10},
number = {3},
doi = {10.1002/cre2.894}
}
EUVIMED