The influence of titanium‐base abutment geometry and height on mechanical stability of implant‐supported single crowns
Clinical Oral Implants Research · 2024-08 · 35 (8) · 1033-1041
DOI: 10.1111/clr.14207 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 27.11.2023. Verfasst von Duygu Karasan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland. Hauptthemen laut MEDLINE: Titanium, Crowns, Dental Prosthesis, Implant-Supported, Dental Stress Analysis. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
Aim
This study aimed to investigate the influence of titanium base (ti‐base) abutment macro‐ and micro‐geometry on the mechanical stability of polymer‐infiltrated ceramic network (PICN) screw‐retained implant‐supported single crowns (iSCs). Materials and Methods Twelve specimens per group were used, comprising six different implant/ti‐base abutment combinations restored with PICN iSCs: Nb‐T (gingival height [GH]: 1.5 mm, prosthetic height [PH]: 4.3 mm), CC (GH: 0.8 mm, PH: 4.3 mm), CC‐P (GH: 0.8 mm, PH: 7 mm), Nb‐V (GH: 1.5 mm, PH: 6 mm), St (GH: 1.5 mm, PH: 5.5 mm), and Th (GH: 0.5 mm, PH: 9 mm). The specimens underwent thermo‐mechanical aging, and those that survived were subsequently subjected to static loading until failure. The data were analyzed using a one‐way ANOVA test followed by Tukey post hoc test ( α = .05).
Results
All specimens survived thermo‐mechanical aging without complications, namely, visible cracks, debonding, or screw loosening. Th group demonstrated the highest strength values among all the groups, with significant differences compared to Nb‐T ( p < .05), CC ( p < .001), and St ( p < .001). Additionally, CC‐P group exhibited significantly superior fracture strength results compared to CC ( p < .05) and St ( p < .05).
Conclusion
The choice of ti‐base, particularly prosthetic height, had a significant influence on fracture resistance of PICN iSCs. Nevertheless, the height or geometrical features of the ti‐base did not exhibit a significant influence on the mechanical behavior of the iSC/ti‐base assembly under thermomechanical loading, as all specimens withstood the aging without complication or failure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
- Department of Comprehensive Dentistry, Peking University and Hospital of Stomatology First Clinical Division, Beijing, China.
ORCID-Profile: Duygu Karasan, João Pitta, Cristina Zarauz, Malin Strasding, Xinran Liu, Vincent Fehmer, Irena Sailer
Zitieren
APA
Karasan, D., Pitta, J., Zarauz, C., Strasding, M., Liu, X., Fehmer, V., & Sailer, I. (2024). The influence of titanium‐base abutment geometry and height on mechanical stability of implant‐supported single crowns. Clinical Oral Implants Research, 35(8), 1033-1041. https://doi.org/10.1111/clr.14207
Vancouver
Karasan D, Pitta J, Zarauz C, Strasding M, Liu X, Fehmer V, et al. The influence of titanium‐base abutment geometry and height on mechanical stability of implant‐supported single crowns. Clinical Oral Implants Research. 2024;35(8):1033-1041. doi:10.1111/clr.14207
BibTeX
@article{Karasan2024,
author = {Karasan, Duygu and Pitta, João and Zarauz, Cristina and Strasding, Malin and Liu, Xinran and Fehmer, Vincent and Sailer, Irena},
title = {The influence of titanium‐base abutment geometry and height on mechanical stability of implant‐supported single crowns},
journal = {Clinical Oral Implants Research},
year = {2024},
volume = {35},
number = {8},
pages = {1033--1041},
doi = {10.1111/clr.14207}
}