Monolithic hybrid abutment crowns: Influence of crown height, crown morphology and material on the implant-abutment complex
Journal of Prosthodontic Research · 2024 · 68 (4) · 606-614
DOI: 10.2186/jpr.jpr_d_23_00253 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontic Research, 2024. Verfasst von Tobias Graf und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Center for Dentistry and Oral Medicine (Carolinum), Goethe University Frankfurt am Main, Frankfurt am Main, Germany. Hauptthemen laut MEDLINE: Crowns, Dental Abutments, Zirconium, Dental Implant-Abutment Design. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 44 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: This in vitro study investigated the influence of material selection, crown morphology, and vertical crown height on the biomechanical behavior of screw-retained monolithic hybrid abutment crowns (HACs). METHODS: Ninety implants were embedded in accordance with ISO standard 14801; ninety HACs were mounted (N=90). Monolithic crowns with varying group-specific designs were luted using titanium bases. HACs were fabricated from monolithic lithium disilicate ceramic (LD) or zirconia-reinforced lithium silicate ceramic (ZLS). The crown morphology was either maxillary premolar (LD_PM, ZLS_PM) or molar (LD_MO). The three groups were further divided into three subgroups of ten specimens, each designed with a small (7.5 mm), middle (10.5 mm), and high (13.5 mm) configuration of crown heights (N=10). A load-to-failure test at 30° off-axis was conducted using a universal testing machine until failure. For statistical analysis, Kolmogorov-Smirnov and Mann-Whitney U tests were conducted (P < 0.05). RESULTS: All LD_MO groups presented the highest failure values (808.7 to 947.9 N), followed by the LD_PM (525.8 to 722.8 N) and ZLS_PM groups (312.6 to 478.8N). A comparison between LD and ZLS materials (P < 0.001) as well as the crown morphology (P < 0.001) showed significant differences in failure values. The values in the subgroups of ZLS_PM (low, middle, high) decreased as the crown height increased. The fracture modes showed no consistent patterns across the test groups. CONCLUSIONS: Material selection, crown morphology, and vertical crown height appear to be important factors that may influence the clinical failure values and patterns of screw-retained single implant crowns.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Center for Dentistry and Oral Medicine (Carolinum), Goethe University Frankfurt am Main, Frankfurt am Main, Germany.
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany.
Zitieren
APA
Graf, T., Völler, E., Erdelt, K., Stimmelmayr, M., Schubert, O., & Güth, J. F. (2024). Monolithic hybrid abutment crowns: Influence of crown height, crown morphology and material on the implant-abutment complex. Journal of Prosthodontic Research, 68(4), 606-614. https://doi.org/10.2186/jpr.jpr_d_23_00253
Vancouver
Graf T, Völler E, Erdelt K, Stimmelmayr M, Schubert O, Güth JF. Monolithic hybrid abutment crowns: Influence of crown height, crown morphology and material on the implant-abutment complex. Journal of Prosthodontic Research. 2024;68(4):606-614. doi:10.2186/jpr.jpr_d_23_00253
BibTeX
@article{Graf2024,
author = {Graf, Tobias and Völler, Elisabeth and Erdelt, Kurt and Stimmelmayr, Michael and Schubert, Oliver and Güth, Jan-Frederik},
title = {Monolithic hybrid abutment crowns: Influence of crown height, crown morphology and material on the implant-abutment complex},
journal = {Journal of Prosthodontic Research},
year = {2024},
volume = {68},
number = {4},
pages = {606--614},
doi = {10.2186/jpr.jpr_d_23_00253}
}