Quick Rinse, Strong Bond? Comparing Short Water Rinsing and Advanced Cleaning Methods After Hydrofluoric Etching of Lithium Disilicate Glass Ceramic
Materials · 12.01.2026 · 19 (2) · 299
DOI: 10.3390/ma19020299 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 12.01.2026. Verfasst von Viktoria Brandl und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, University Hospital Schleswig-Holstein, Campus Kiel, Christian Albrecht University of Kiel, Arnold-Heller-Str. 3, 24105…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study examined whether short water rinsing after hydrofluoric acid (HF) etching achieves comparable total bond strength (TBS) to more advanced cleaning protocols. Ninety-six lithium disilicate specimens were etched with 5% HF and then assigned to one of six post-etch cleaning methods: a 15 s water spray, 60 s water spray, brushing with a toothbrush, an ultrasonic bath with distilled water, an ultrasonic bath with 99% isopropanol, or a 37% phosphoric acid followed by an ultrasonic bath. The specimens were then bonded to acrylic tubes filled with composite resin. Half of the specimens were stored in water at 37 °C for three days, and the other half were stored for 150 days with 37,500 thermal cycles (5 °C/55 °C). TBS testing, failure mode evaluation, and microleakage testing were performed. Two-way ANOVA and Tukey’s test were used for statistical evaluation. Aging for 150 days significantly reduced TBS in all groups. Cleaning with a 60 s water spray resulted in significantly higher TBS than phosphoric acid plus ultrasonic cleaning, regardless of storage time. No significant differences were found among the other cleaning methods. There was no change in microleakage among the different groups; the failure was predominantly cohesive. A 15 s water spray after HF etching was as effective as more complex cleaning protocols in terms of TBS and SEM-observed surface characteristics.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, University Hospital Schleswig-Holstein, Campus Kiel, Christian Albrecht University of Kiel, Arnold-Heller-Str. 3, 24105 Kiel, Germany.
ORCID-Profile: Matthias Kern, Maximiliane Amelie Schlenz
Zitieren
APA
Brandl, V., Kern, M., Schlenz, M. A., & Wille, S. (2026). Quick Rinse, Strong Bond? Comparing Short Water Rinsing and Advanced Cleaning Methods After Hydrofluoric Etching of Lithium Disilicate Glass Ceramic. Materials, 19(2), 299. https://doi.org/10.3390/ma19020299
Vancouver
Brandl V, Kern M, Schlenz MA, Wille S. Quick Rinse, Strong Bond? Comparing Short Water Rinsing and Advanced Cleaning Methods After Hydrofluoric Etching of Lithium Disilicate Glass Ceramic. Materials. 2026;19(2):299. doi:10.3390/ma19020299
BibTeX
@article{Brandl2026,
author = {Brandl, Viktoria and Kern, Matthias and Schlenz, Maximiliane Amelie and Wille, Sebastian},
title = {Quick Rinse, Strong Bond? Comparing Short Water Rinsing and Advanced Cleaning Methods After Hydrofluoric Etching of Lithium Disilicate Glass Ceramic},
journal = {Materials},
year = {2026},
volume = {19},
number = {2},
pages = {299},
doi = {10.3390/ma19020299}
}