Relevant Aspects of the Dental Implant Design on the Insertion Torque, Resonance Frequency Analysis (RFA) and Micromobility: An In Vitro Study
Journal of Clinical Medicine · 20.01.2023 · 12 (3) · 855
DOI: 10.3390/jcm12030855 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 20.01.2023. Verfasst von Mariano Herrero-Climent und 5 weiteren Autor:innen. Beteiligte Einrichtung: Porto Dental Institute, Av. de Montevideu 810, 4150-518 Porto, Portugal. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The major problems for the osseointegration of dental implants are the loosening of the screw that fixes the dental implant to the abutment and the micromovements that are generated when mechanical loads are applied. In this work, torque differences in the tightening and loosening of the connection screws after 1 cycle, 10 cycles and 1000 cycles for 4 dental implants with 2 external and 2 internal connections were analyzed. The loosening of 240 implants (60 for each system) was determined using high-precision torsimeters and an electromechanical testing machine. A total of 60 dental implants for each of the 4 systems were inserted into fresh bovine bone to determine the micromovements. The implant stability values (ISQ) were determined by RFA. The mechanical loads were performed at 30° from 20 N to 200 N. By means of the Q-star technique, the micromovements were determined. It was observed that, for a few cycles, the loosening of the screw did not exceed a loss of tightening of 10% for both connections. However, for 1000 cycles, the loss for the external connection was around 20% and for the internal connection it was 13%. The micromovements showed a lineal increase with the applied load for the implant systems studied. An external connection presented greater micromotions for each level of applied load and lower ISQ values than internal ones. An excellent lineal correlation between the ISQ and micromobility was observed. These results may be very useful for clinicians in the selection of the type of dental implant, depending on the masticatory load of the patient as well as the consequences of the insertion torque of the dental implant and its revisions.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Porto Dental Institute, Av. de Montevideu 810, 4150-518 Porto, Portugal.
- Centre for Innovation and Research in Oral Sciences (CIROS), Faculty of Medicine, University of Coimbra, Rua Larga 2, 3004-531 Coimbra, Portugal.
- Facultad de Odontología, Universidad Europea Miguel de Cervantes, C/del Padre Julio Chevalier 2, 47012 Valladolid, Spain.
- Department of Periodontology, Faculty of Dentsitry, University of Seville, 41009 Sevilla, Spain.
- Bioengineering Institute of Technology, Facultad de Medicina y Ciencias de la Salud, International University of Catalonia, Sant Cugat del Vallés, 08195 Barcelona, Spain.
ORCID-Profile: Mariano Herrero-Climent, Joao Tondela, Blanca Rios-Carrasco, Javier Gil
Zitieren
APA
Herrero-Climent, M., Falcao, A., Tondela, J., Brizuela, A., Rios-Carrasco, B., & Gil, J. (2023). Relevant Aspects of the Dental Implant Design on the Insertion Torque, Resonance Frequency Analysis (RFA) and Micromobility: An In Vitro Study. Journal of Clinical Medicine, 12(3), 855. https://doi.org/10.3390/jcm12030855
Vancouver
Herrero-Climent M, Falcao A, Tondela J, Brizuela A, Rios-Carrasco B, Gil J. Relevant Aspects of the Dental Implant Design on the Insertion Torque, Resonance Frequency Analysis (RFA) and Micromobility: An In Vitro Study. Journal of Clinical Medicine. 2023;12(3):855. doi:10.3390/jcm12030855
BibTeX
@article{HerreroCliment2023,
author = {Herrero-Climent, Mariano and Falcao, Artur and Tondela, Joao and Brizuela, Aritza and Rios-Carrasco, Blanca and Gil, Javier},
title = {Relevant Aspects of the Dental Implant Design on the Insertion Torque, Resonance Frequency Analysis (RFA) and Micromobility: An In Vitro Study},
journal = {Journal of Clinical Medicine},
year = {2023},
volume = {12},
number = {3},
pages = {855},
doi = {10.3390/jcm12030855}
}
EUVIMED