Rethinking Implant Length: A Density‐Dependent Analysis of Primary Stability—An In Vitro Evaluation Using Resonance Frequency Analysis and Insertion Torque
International Journal of Dentistry · 2026-01 · 2026 (1)
DOI: 10.1155/ijod/4201028 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Dentistry, online erschienen am 19.06.2026. Verfasst von Sergio Alexandre Gehrke und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Science, School of Health Sciences, Vale do Itajai University (UNIVALI), Itajai, 88302-901, Brazil. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Accurate assessment of the primary stability of dental implants is essential for predicting osseointegration and determining loading protocols. This in vitro study aimed to evaluate the primary stability of dental implants of varying lengths across simulated bone densities using the insertion torque value (ITV) and resonance frequency analysis (RFA). Materials and Methods Morse‐taper implants (5.0 mm diameter) were divided into four groups based on length: 5, 6, 7, and 8 mm. Implants were placed into polyurethane foam blocks of varying densities: PCF 40, PCF 30 (with 2 and 1 mm cortical layers), and PCF 20 (with a 1 mm cortical layer). Primary stability was measured via ITV and RFA, yielding an implant stability quotient (ISQ).
Results
In high‐density foam (PCF 40), both ITV and ISQ increased proportionally with implant length, with the 8 mm implant demonstrating the highest stability (ITV = 109.26 ± 4.79 Ncm and ISQ = 73.5 ± 2.32). Conversely, in low‐density foam (PCF 20/1 mm), a direct relationship was observed, where the shortest implant (5 mm) exhibited the lowest stability (ITV = 36.8 ± 3.27 Ncm and ISQ = 45.8 ± 2.66), whereas the highest stability was presented by the 8 mm implant (ITV = 61.36 ± 2.00 Ncm and ISQ = 56.3 ± 2.67).
Conclusion
Implant length significantly influences primary stability, but its effect is highly dependent on bone density. While shorter implants provide sufficient primary stability and may reduce surgical risks in highly dense bone, increased implant length is crucial for achieving superior primary stability in poor‐quality bone with thin cortical plates.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pharmaceutical Science, School of Health Sciences, Vale do Itajai University (UNIVALI), Itajai, 88302-901, Brazil.
- Department of Implantology, Bioface/Catolica de Murcia University, Montevideo, 11100, Uruguay.
- Missouri School of Dentistry and Oral Health, A. T. Still University, St. Louis, 63104, Missouri, USA, atsu.edu.
- GF10 Foundation, St. Louis, 63014, Missouri, USA.
- Center for Interdisciplinary Research in Health (CIIS) - Universidade Católica Portuguesa (UCP), Viseu, Portugal.
ORCID-Profile: Sergio Alexandre Gehrke, Gracey Mosley, Juliana Campos Hasse Fernandes, Gustavo Vicentis Oliveira Fernandes
Zitieren
APA
Gehrke, S. A., Mosley, G., Fernandes, J. C. H., & Fernandes, G. V. O. (2026). Rethinking Implant Length: A Density‐Dependent Analysis of Primary Stability—An In Vitro Evaluation Using Resonance Frequency Analysis and Insertion Torque. International Journal of Dentistry, 2026(1). https://doi.org/10.1155/ijod/4201028
Vancouver
Gehrke SA, Mosley G, Fernandes JCH, Fernandes GVO. Rethinking Implant Length: A Density‐Dependent Analysis of Primary Stability—An In Vitro Evaluation Using Resonance Frequency Analysis and Insertion Torque. International Journal of Dentistry. 2026;2026(1). doi:10.1155/ijod/4201028
BibTeX
@article{Gehrke2026,
author = {Gehrke, Sergio Alexandre and Mosley, Gracey and Fernandes, Juliana Campos Hasse and Fernandes, Gustavo Vicentis Oliveira},
title = {Rethinking Implant Length: A Density‐Dependent Analysis of Primary Stability—An In Vitro Evaluation Using Resonance Frequency Analysis and Insertion Torque},
journal = {International Journal of Dentistry},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/ijod/4201028}
}
EUVIMED