Influence of Light-Curing Parameters on the Physicomechanical and Polymerization Properties of Bulk-Fill Resin Composites: A Scoping Review
Dentistry Journal · 22.11.2026 · 14 (12) · 763
DOI: 10.3390/dj14120763 ↗Kurz gefasst
Scoping Review in der Zeitschrift Dentistry Journal, online erschienen am 22.11.2026. Verfasst von Alexandra Vigu und 4 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Iuliu Hatieganu University of Medicine and Pharmacy Cluj-Napoca.
Abstract (Originalsprache)
Background
Bulk-fill resin composites allow placement in thicker increments, but adequate polymerization depends on effective light transmission and appropriate irradiation. Differences in light-curing unit (LCU) spectral emission, irradiance, exposure time, curing mode, and tip-to-restoration distance may influence their polymerization and subsequent properties. This review aimed to evaluate the influence of different light-curing protocols on the performance of bulk-fill resin composites.
Methods
The available literature investigating light curing of bulk-fill resin composites was reviewed, with emphasis on LCU characteristics and irradiation parameters. Outcomes included degree of conversion, hardness, depth of cure, mechanical properties, optical behavior, interfacial adaptation, and clinical performance. Sixteen studies meeting the review criteria were analyzed.
Results
Most studies focused on laboratory measures of polymerization efficiency, particularly degree of conversion and hardness. Overall, adequate polymerization depended on both material composition and irradiation conditions. Polywave LCUs provided advantages for some composites containing multiple photoinitiators, whereas monowave and polywave units produced comparable results for other materials. Increased curing distance generally impaired polymerization, while the effectiveness of short, high-irradiance protocols was material-dependent and did not consistently reproduce the performance achieved with manufacturer-recommended exposure times. Optical properties, light transmission, mechanical behavior, and interfacial adaptation were likewise influenced by material-specific characteristics and curing conditions.
Conclusions
No single light-curing protocol can be considered universally optimal for bulk-fill resin composites. Curing effectiveness reflects the interaction between LCU spectral and energy characteristics, irradiation parameters, restoration geometry, and composite formulation. Standardized laboratory methodologies and long-term clinical studies are needed to establish clinically relevant evidence-based curing protocols.
Förderung
- Iuliu Hatieganu University of Medicine and Pharmacy Cluj-Napoca
Zitieren
APA
Vigu, A., Labunet, A., Rusu, L., Voina-Tonea, A., & Sava, S. (2026). Influence of Light-Curing Parameters on the Physicomechanical and Polymerization Properties of Bulk-Fill Resin Composites: A Scoping Review. Dentistry Journal, 14(12), 763. https://doi.org/10.3390/dj14120763
Vancouver
Vigu A, Labunet A, Rusu L, Voina-Tonea A, Sava S. Influence of Light-Curing Parameters on the Physicomechanical and Polymerization Properties of Bulk-Fill Resin Composites: A Scoping Review. Dentistry Journal. 2026;14(12):763. doi:10.3390/dj14120763
BibTeX
@article{Vigu2026,
author = {Vigu, Alexandra and Labunet, Anca and Rusu, Laura and Voina-Tonea, Andrada and Sava, Sorina},
title = {Influence of Light-Curing Parameters on the Physicomechanical and Polymerization Properties of Bulk-Fill Resin Composites: A Scoping Review},
journal = {Dentistry Journal},
year = {2026},
volume = {14},
number = {12},
pages = {763},
doi = {10.3390/dj14120763}
}
EUVIMED