Comparative Analysis of Twenty Intraocular Lens Power Calculation Formulas in Medium-Long Eyes
Diagnostics · 21.07.2026 · 16 (14) · 2281
DOI: 10.3390/diagnostics16142281 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 21.07.2026. Verfasst von Wiktor Stopyra und 2 weiteren Autor:innen. Beteiligte Einrichtung: MW-Med Eye Center, 31-416 Krakow, Poland. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: The choice of appropriate intraocular lens (IOL) power calculation formulas depends on the axial length of the eye. This study compares the accuracy of twenty formulas in medium-long eyes (24.50–25.99 mm).
Methods
Data of patients with medium-long eyes, who underwent uneventful phacoemulsification between January 2018 and September 2023, were retrospectively reviewed. Preoperative IOL power was calculated using the IOLMaster 700 with six formulas: Barrett Universal II, Haigis, Hoffer Q, Holladay 1, Holladay 2, and SRK/T. Three months postoperatively, refraction was measured. Postoperative IOL power calculations were then performed using fourteen additional formulas: Castrop, EVO 2.0, Hoffer QST, K6, Kane, Karmona, Ladas Super Formula AI (LSF AI), Naeser 2, Olsen (OLCR), Olsen (standalone), PEARL-DGS, T2, VRF CMAL, and VRF-G. The main outcome measures included standard deviation (SD) of the prediction error (PE) and the percentage of eyes with PE within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D.
Results
Ninety-five eyes with axial lengths ranging from 24.52 mm to 25.97 mm were included. SD values among the twenty formulas ranged from 0.179 (SRK/T) to 0.468 (Olsen OLCR). The percentage of eyes with PE within ±0.50 D ranged from 75.79% (Olsen OLCR) to 98.95% (SRK/T). The SRK/T formula, followed by Holladay 1, demonstrated significantly higher accuracy than most other formulas, while Olsen (OLCR) and Castrop were the least accurate.
Conclusions
SRK/T provided the highest accuracy in medium-long eyes, with Holladay 1 performing similarly well. All evaluated formulas achieved PE within ±0.50 D in over 74% of cases.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- MW-Med Eye Center, 31-416 Krakow, Poland.
- Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, 03680 Kyiv, Ukraine.
- Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, 60-836 Poznan, Poland.
- Department of Ophthalmology, University of Warmia and Mazury in Olsztyn, 10-719 Olsztyn, Poland.
ORCID-Profile: Wiktor Stopyra, Oleksiy Voytsekhivskyy
Zitieren
APA
Stopyra, W., Voytsekhivskyy, O., & Grzybowski, A. (2026). Comparative Analysis of Twenty Intraocular Lens Power Calculation Formulas in Medium-Long Eyes. Diagnostics, 16(14), 2281. https://doi.org/10.3390/diagnostics16142281
Vancouver
Stopyra W, Voytsekhivskyy O, Grzybowski A. Comparative Analysis of Twenty Intraocular Lens Power Calculation Formulas in Medium-Long Eyes. Diagnostics. 2026;16(14):2281. doi:10.3390/diagnostics16142281
BibTeX
@article{Stopyra2026,
author = {Stopyra, Wiktor and Voytsekhivskyy, Oleksiy and Grzybowski, Andrzej},
title = {Comparative Analysis of Twenty Intraocular Lens Power Calculation Formulas in Medium-Long Eyes},
journal = {Diagnostics},
year = {2026},
volume = {16},
number = {14},
pages = {2281},
doi = {10.3390/diagnostics16142281}
}
EUVIMED