EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Comparison of the accuracy of twenty intraocular lens power calculation formulas in long eyes

Wiktor Stopyra, Oleksiy Voytsekhivskyy, Andrzej Grzybowski

Asia-Pacific Journal of Ophthalmology · 2025-05 · 14 (3) · 100198

DOI: 10.1016/j.apjo.2025.100198 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Asia-Pacific Journal of Ophthalmology, 2025-05. Verfasst von Wiktor Stopyra und 2 weiteren Autor:innen. Beteiligte Einrichtung: MW-med Eye Center, Krakow 31-416, Poland; University of Applied Sciences, Nowy Targ 34-400, Poland. Electronic address: wiktorstopyra@gmail.com. Hauptthemen laut MEDLINE: Lenses, Intraocular, Refraction, Ocular, Optics and Photonics, Axial Length, Eye. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare the accuracy of twenty intraocular lens (IOL) power calculation formulas in long eyes (26.00-29.99 mm) DESIGN: Retrospective accuracy and validity analysis METHODS: The data of patients who underwent uneventful phacoemulsification between August 2019 and July 2024 were reviewed. Pre-surgery IOL power was calculated using Haigis, Holladay 2, SRK/T and Barrett Universal II formulas. Three months after cataract surgery, refraction was measured. Post-surgery IOL power calculations were performed utilizing the following formulas: Castrop, EVO 2.0, Hill-RBF 3.0, Hoffer Q, Holladay 1, Hoffer QST, K6, Kane, Karmona, Ladas Super Formula AI (LSF AI), Naeser 2, Olsen (standalone), PEARL-DGS, T2, VRF and VRF-G. Root mean square absolute error (RMSAE), median absolute error (MedAE) and percentage of eyes with prediction error (PE) within ± 0.25 D, ± 0.50 D, ± 0.75 D and ± 1.00 were calculated. RESULTS: One hundred fifty-three eyes with axial length ranging between 26.00 mm and 29.47 mm, were studied. The SRK/T formula yielded the lowest RMSAE (0.349) with statistical superiority over Holladay 1 (0.519, P = 0.000), Olsen (standalone) (0.505, P = 0.000) and Hoffer Q (0.497, P = 0.000). In terms of MedAE, the lowest outcome was obtained by VRF-G (0.256) followed by Barrett Universal II, Hill-RBF 3.0 and LSF AI (all equally of 0.260). The highest percentage of eyes with prediction error within ± 0.50 D was achieved by SRK/T (84.97 %) statistically significant vs Holladay 1 (60.78 %), Hoffer Q (64.05 %) and Olsen(standalone) (68.63 %). CONCLUSIONS: SRK/T has delivered highly accurate results in long eyes. Barrett Universal II, Hill-RBF 3.0, VRF-G and LSF AI are also very true.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularRefraction, OcularOptics and PhotonicsAxial Length, EyePhacoemulsificationBiometryLens Implantation, IntraocularHumansRetrospective StudiesMaleFemaleAgedMiddle AgedVisual AcuityReproducibility of ResultsAged, 80 and over

Stichwörter der Autor:innen

Intraocular lenses, SRK/T formulaLong eyesPhacoemulsification

Autor:innen und Institutionen

  • MW-med Eye Center, Krakow 31-416, Poland; University of Applied Sciences, Nowy Targ 34-400, Poland. Electronic address: wiktorstopyra@gmail.com.
  • Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Kyiv 03680, Ukraine.
  • Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, Poznan 61-553, Poland; Department of Ophthalmology, University of Warmia and Mazury, Olsztyn 10-720, Poland. Electronic address: ae.grzy…

Zitieren

APA

Stopyra, W., Voytsekhivskyy, O., & Grzybowski, A. (2025). Comparison of the accuracy of twenty intraocular lens power calculation formulas in long eyes. Asia-Pacific Journal of Ophthalmology, 14(3), 100198. https://doi.org/10.1016/j.apjo.2025.100198

Vancouver

Stopyra W, Voytsekhivskyy O, Grzybowski A. Comparison of the accuracy of twenty intraocular lens power calculation formulas in long eyes. Asia-Pacific Journal of Ophthalmology. 2025;14(3):100198. doi:10.1016/j.apjo.2025.100198

BibTeX
@article{Stopyra2025,
  author = {Stopyra, Wiktor and Voytsekhivskyy, Oleksiy and Grzybowski, Andrzej},
  title = {Comparison of the accuracy of twenty intraocular lens power calculation formulas in long eyes},
  journal = {Asia-Pacific Journal of Ophthalmology},
  year = {2025},
  volume = {14},
  number = {3},
  pages = {100198},
  doi = {10.1016/j.apjo.2025.100198}
}
Kostenlos starten →