EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY-NC-ND 4.0

Accuracy of sixteen axial length adjusted intraocular lens power calculation formulas in long Caucasian eyes

Wiktor Stopyra, Oleksiy Voytsekhivskyy, Andrzej Grzybowski

Asia-Pacific Journal of Ophthalmology · 2026-03 · 15 (2) · 100301

DOI: 10.1016/j.apjo.2026.100301 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Asia-Pacific Journal of Ophthalmology, 2026-03. Verfasst von Wiktor Stopyra und 2 weiteren Autor:innen. Beteiligte Einrichtung: MW-med Eye Center, Poland. Hauptthemen laut MEDLINE: Axial Length, Eye, Biometry, Lenses, Intraocular, Myopia. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Alcon, Bausch and Lomb, CooperVision.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To compare the accuracy of sixteen intraocular lens (IOL) power calculation formulas incorporating targeted adjustments or regression-based modifications of axial length (AL) in eyes longer than 26.00 mm. DESIGN: Retrospective observational study. METHODS: The data of myopic patients with cataract who underwent uneventful phacoemulsification with in-the-bag implantation of a PARTIAL-RoF narrow IOL between January 2020 and June 2025 were reviewed. Preoperative IOL power was calculated using the IOLMaster 700 with six formulas: Barrett Universal II (BU II), Haigis, Hoffer Q, Holladay 1, Holladay 2, and SRK/T. The implanted IOL power was selected from BU II or SRK/T recommendations. Refraction was measured three months postoperatively. Postoperative IOL power predictions were generated using the following formulas or formula variants: K6, PEARL-DGS, Castrop, Eom, VRF CMAL; Holladay 1 with Wang-Koch 2 center optimization (WK2), modified Wang-Koch (MWK), non-linear regression (NLR), and Fam-adjusted method (F2); SRK/T WK2, SRK/T MWK, SRK/T F2; Holladay 2 NLR; Hoffer Q WK2; Haigis WK2; and Barrett True AL. The primary outcome measures were root mean square absolute error (RMSAE) and the percentage of eyes with prediction error (PE) within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D. RESULTS: One hundred sixty-four eyes with ALs ranging from 26.04 mm to 29.72 mm were included. RMSAE values across the sixteen formulas ranged from 0.393 (Holladay 1 NLR and SRK/T WK2) to 0.803 (Haigis WK2). The percentage of eyes with PE within ±0.50 D ranged from 35.98% (Haigis WK2) to 81.1% (Holladay 1 NLR). Holladay 1 NLR-followed by SRK/T WK2, Holladay 1 MWK, VRF CMAL, PEARL-DGS, and Eom-demonstrated significantly higher accuracy than most other formulas. Haigis WK2 and Hoffer Q WK2 were the least accurate. CONCLUSIONS: Certain modified third-generation formulas (Holladay 1 NLR, SRK/T WK2) achieve accuracy comparable to that of new-generation formulas (PEARL-DGS, K6, VRF CMAL) in IOL power calculations for long eyes. However, some third- and fourth-generation formulas-even after AL-based modification (Hoffer Q WK2, Haigis WK2)-continue to yield suboptimal results in this anatomical range.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Axial Length, EyeBiometryLenses, IntraocularMyopiaOptics and PhotonicsRefraction, OcularAgedFemaleHumansMaleMiddle AgedLens Implantation, IntraocularPhacoemulsificationRetrospective StudiesVisual AcuityWhite People

Stichwörter der Autor:innen

Cataract surgeryHolladay 1 formulaIntraocular lensesLong eyes

Autor:innen und Institutionen

  • MW-med Eye Center, Poland.
  • Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Ukraine.
  • Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, Poland; Department of Ophthalmology, University of Warmia and Mazury, Poland. Electronic address: ae.grzybowski@gmail.com.

Förderung

  • Alcon
  • Bausch and Lomb
  • CooperVision

Zitieren

APA

Stopyra, W., Voytsekhivskyy, O., & Grzybowski, A. (2026). Accuracy of sixteen axial length adjusted intraocular lens power calculation formulas in long Caucasian eyes. Asia-Pacific Journal of Ophthalmology, 15(2), 100301. https://doi.org/10.1016/j.apjo.2026.100301

Vancouver

Stopyra W, Voytsekhivskyy O, Grzybowski A. Accuracy of sixteen axial length adjusted intraocular lens power calculation formulas in long Caucasian eyes. Asia-Pacific Journal of Ophthalmology. 2026;15(2):100301. doi:10.1016/j.apjo.2026.100301

BibTeX
@article{Stopyra2026,
  author = {Stopyra, Wiktor and Voytsekhivskyy, Oleksiy and Grzybowski, Andrzej},
  title = {Accuracy of sixteen axial length adjusted intraocular lens power calculation formulas in long Caucasian eyes},
  journal = {Asia-Pacific Journal of Ophthalmology},
  year = {2026},
  volume = {15},
  number = {2},
  pages = {100301},
  doi = {10.1016/j.apjo.2026.100301}
}