Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes

Xinxin Li, Chunyuan Song, Yong Wang, Jing Wang, Qiongyan Tang, Zheming Wu, Yanwen Zhou, Juan Sun, Yanhong Jia, Zhenlin Lin, Shaowei Li

Graefe's Archive for Clinical and Experimental Ophthalmology · 2024-11 · 262 (11) · 3619-3628

DOI: 10.1007/s00417-024-06506-w ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, online erschienen am 17.05.2024. Verfasst von Xinxin Li und 10 weiteren Autor:innen. Beteiligte Einrichtung: Aier School of Ophthalmology, Central South University, Changsha, 410015, China. Hauptthemen laut MEDLINE: Lenses, Intraocular, Refraction, Ocular, Axial Length, Eye, Biometry. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Project Supported by Science and Technology Innovation Program of Socialization Investment of Hunan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare the accuracy of 14 formulas in calculating intraocular lens (IOL) power in extremely long eyes with axial length (AL) over 30.0 mm. METHODS: In this retrospective study, 211 eyes (211 patients) with ALs > 30.0 mm were successfully treated with cataract surgery without complications. Ocular biometric parameters were obtained from IOLMaster 700. Fourteen formulas were evaluated using the optimized A constants: Barrett Universal II (BUII), Kane, Emmetropia Verifying Optical (EVO) 2.0, PEARL-DGS, T2, SRK/T, Holladay 1, Holladay 2, Haigis and Wang-Koch AL adjusted formulas (SRK/Tmodified-W/K, Holladay 1modified-W/K, Holladay 1NP-modified-W/K, Holladay 2modified-W/K, Holladay 2NP-modified-W/K). The mean prediction error (PE) and standard deviation (SD), mean absolute errors (MAE), median absolute errors (MedAE), and the percentage of prediction errors (PEs) within ± 0.25 D, ± 0.50 D, ± 1.00 D were analyzed. RESULTS: The Kane formula had the smallest MAE (0.43 D) and MedAE (0.34 D). The highest percentage of PE within ± 0.25 D was for EVO 2.0 (37.91%) and the Holladay 1NP-modified-W/K formulas (37.91%). The Kane formula had the highest percentage of PEs in the range of ± 0.50, ± 0.75, ± 1.00, and ± 2.00 D. There was no significant difference in PEs within ± 0.25, ± 0.50 ± 0.75 and ± 1.00 D between BUII, Kane, EVO 2.0 and Wang-Koch AL adjusted formulas (P > .05) by using Cochran's Q test. The Holladay 2modified-W/K formula has the lowest percentage of hyperopic outcomes (29.38%). CONCLUSIONS: The BUII, Kane, EVO 2.0 and Wang-Koch AL adjusted formulas have comparable accuracy for IOL power calculation in eyes with ALs > 30.0 mm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularRefraction, OcularAxial Length, EyeBiometryOptics and PhotonicsHumansRetrospective StudiesFemaleMaleAgedMiddle AgedReproducibility of ResultsVisual AcuityAged, 80 and overAdultLens Implantation, Intraocular

Stichwörter der Autor:innen

CalculationCataract surgeryExtremely long axial lengthFormulaIntraocular lens power

Autor:innen und Institutionen

  • Aier School of Ophthalmology, Central South University, Changsha, 410015, China.
  • Aier Eye Hospital, Jinan University, Guangzhou, 510071, China.
  • Wuhan Aier Eye Hospital, Wuhan, 430063, China.
  • Shenyang Aier Excellence Eye Hospital, Shenyang, 110001, China.
  • Changsha Aier Eye Hospital, Changsha, 410015, China.
  • Guangzhou Aier Eye Hospital, Guangzhou, 510000, China.

Förderung

  • Project Supported by Science and Technology Innovation Program of Socialization Investment of Hunan Province

Zitieren

APA

Li, X., Song, C., Wang, Y., Wang, J., Tang, Q., Wu, Z., Zhou, Y., Sun, J., Jia, Y., Lin, Z., & Li, S. (2024). Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes. Graefe's Archive for Clinical and Experimental Ophthalmology, 262(11), 3619-3628. https://doi.org/10.1007/s00417-024-06506-w

Vancouver

Li X, Song C, Wang Y, Wang J, Tang Q, Wu Z, et al. Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes. Graefe's Archive for Clinical and Experimental Ophthalmology. 2024;262(11):3619-3628. doi:10.1007/s00417-024-06506-w

BibTeX
@article{Li2024,
  author = {Li, Xinxin and Song, Chunyuan and Wang, Yong and Wang, Jing and Tang, Qiongyan and Wu, Zheming and Zhou, Yanwen and Sun, Juan and Jia, Yanhong and Lin, Zhenlin and Li, Shaowei},
  title = {Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2024},
  volume = {262},
  number = {11},
  pages = {3619--3628},
  doi = {10.1007/s00417-024-06506-w}
}
Kostenlos starten →