EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of Analog and Digital Full-Arch Mandibular Impressions: In Vitro and In Vivo Evaluation

Diana Cerghizan iD, Kinga Mária Jánosi iD, Alexandra Farcas, Marcel Mihai Bojan iD, Mircea Horia Muntean, Andreea Ana Maria Nechiti, Izabella Éva Mureșan, Silvia Izabella Pop iD, Gyula Marada iD

Diagnostics · 19.08.2025 · 15 (16) · 2077

DOI: 10.3390/diagnostics15162077 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 19.08.2025. Verfasst von Diana Cerghizan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Dental Medicine, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Târgu Mureș, 38 Gh. Marinescu Str., 540139…. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, UEFISCDI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Accurate full-arch impressions are crucial for predictable prosthodontic outcomes. While intraoral scanners (IOSs) are increasingly adopted, evidence comparing their accuracy with conventional analog impressions across full mandibular arches—particularly under both laboratory and clinical conditions using an objective intraoral reference—is limited. Our study aims to evaluate the in vitro and in vivo accuracy of digital impressions compared to conventional methods in full-arch scans using an intraoral reference tool.

Methods

In this study, a custom stainless steel transfer aid carrying four 5 mm steel spheres in a trapezoidal configuration, provided with known reference distances, was used. Ten mandibular Frasaco models (in vitro) and ten healthy young adults (18–30 yrs) with intact lower arches (in vivo) received the bonded spheres. Six inter-sphere distances were defined: intermolar (BL-BR), interpremolar (FL-FR), diagonals (BL-FR, FL-BR), and lateral spans (BL-FL, BR-FR). Each arch underwent a digital scan (Medit i700) and a conventional monophase PVS impression, which was poured in Type IV stone and digitized (GOM Scan 1). The inter-sphere linear distances were measured in GOM Inspect, and trueness (deviation from reference) and precision (SD) were calculated. Data normality and homogeneity were verified; parametric t-tests and one-sample tests (α = 0.05) assessed differences between workflows and against reference values.

Results

In vitro, analog impressions closely matched reference distances, with only the long-span BL-BR showing minor deviation (0.053 mm, p < 0.001). Digital scans showed significantly greater deviations across all spans (max 0.117 mm), particularly over long distances. In vivo, both workflows demonstrated comparable accuracy: only BL-BR (analog) and BR-FR (digital) differed significantly from the reference, and all AMEs remained within clinical thresholds (≤0.10 mm), except for BL-BR and BL-FL spans. ICC values ranged from moderate to high. Direct paired comparisons revealed statistically equivalent performance across most spans.

Conclusions

Analog impressions outperformed digital scans in vitro, particularly across longer spans, confirming their superior dimensional fidelity under controlled conditions. However, in vivo, both workflows delivered statistically comparable and clinically acceptable accuracy. These findings suggest that while analog impressions remain the gold standard for precision-demanding contexts, modern intraoral scanners—when used correctly—can offer reliable full-arch mandibular impressions. The four-sphere reference system proved valuable for objective, anatomy-independent measurement.

Schlagwörter

Stichwörter der Autor:innen

accuracyconventional impressiondigital impressionintraoral scannertransfer aid

Autor:innen und Institutionen

  • Faculty of Dental Medicine, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Târgu Mureș, 38 Gh. Marinescu Str., 540139 Târgu Mureș, Romania.
  • Department of Isotopic and Molecular Technologies, National Institute for Research and Development of Iso-Topic and Molecular Technologies, 67-103 Donat Street, 400293 Cluj-Napoca, Romania.
  • Manufacturing Engineering Department, Faculty of Industrial Engineering, Robotics and Production Management, Technical University of Cluj-Napoca, B-dul Muncii, 103-105, 400641 Cluj-Napoca, Romania.
  • Department of Prosthodontics, Faculty of Medicine, University of Pécs, Tüzér Street 1., H-7625 Pécs, Hungary.

ORCID-Profile: Diana Cerghizan, Kinga Mária Jánosi, Marcel Mihai Bojan, Silvia Izabella Pop, Gyula Marada

Förderung

  • George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș
  • UEFISCDI

Zitieren

APA

Cerghizan, D., Jánosi, K. M., Farcas, A., Bojan, M. M., Muntean, M. H., Nechiti, A. A. M., Mureșan, I. É., Pop, S. I., & Marada, G. (2025). Accuracy of Analog and Digital Full-Arch Mandibular Impressions: In Vitro and In Vivo Evaluation. Diagnostics, 15(16), 2077. https://doi.org/10.3390/diagnostics15162077

Vancouver

Cerghizan D, Jánosi KM, Farcas A, Bojan MM, Muntean MH, Nechiti AAM, et al. Accuracy of Analog and Digital Full-Arch Mandibular Impressions: In Vitro and In Vivo Evaluation. Diagnostics. 2025;15(16):2077. doi:10.3390/diagnostics15162077

BibTeX
@article{Cerghizan2025,
  author = {Cerghizan, Diana and Jánosi, Kinga Mária and Farcas, Alexandra and Bojan, Marcel Mihai and Muntean, Mircea Horia and Nechiti, Andreea Ana Maria and Mureșan, Izabella Éva and Pop, Silvia Izabella and Marada, Gyula},
  title = {Accuracy of Analog and Digital Full-Arch Mandibular Impressions: In Vitro and In Vivo Evaluation},
  journal = {Diagnostics},
  year = {2025},
  volume = {15},
  number = {16},
  pages = {2077},
  doi = {10.3390/diagnostics15162077}
}
Kostenlos starten →