Accuracy of maxillary full‐arch digital impressions of tooth and implant models made by two intraoral scanners
Clinical and Experimental Dental Research · 2024-04 · 10 (2)
DOI: 10.1002/cre2.857 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Experimental Dental Research, online erschienen am 03.03.2024. Verfasst von Hakimeh Siadat und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, School of Dentistry, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehra…. Hauptthemen laut MEDLINE: Dental Implants. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences.
Abstract (Originalsprache)
Objectives
Limited studies are available on the accuracy of intraoral scanners (IOSs) for full‐arch implant and tooth models. This study aimed to assess the accuracy of maxillary full‐arch digital impressions of tooth and implant models made by two IOSs. Materials and Methods This in vitro, experimental study was conducted on two maxillary dentiform models: one with six prepared natural teeth and the other with six implants at the site of canine, first premolar, and first molar teeth, bilaterally. A highly accurate industrial scanner was used for actual measurements on the models that served as the reference scan. TS (Trios3) and CO (CEREC Omnicam) IOSs were then used to scan each model 10 times according to the manufacturer's instructions. All scans were saved in STL format. The GOM Inspect software was used according to the best‐fit algorithm to compare the accuracy of measurements in the groups with the reference scan. The trueness and precision were calculated. Statistical analyses were carried out using SPSS by one‐way analysis of variance and t ‐test ( α = .05).
Results
TS showed a significantly higher trueness than CO for both tooth and implant models ( p < .05). TS also revealed significantly higher precision than CO for the tooth model; however, the difference in precision for the implant model was not significant between the two IOSs ( p > .05).
Conclusions
TS showed higher accuracy than CO in both tooth and implant models.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, School of Dentistry, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales, Australia.
- Department of Prosthodontics, School of Dentistry, Arak University of Medical Sciences, Arak, Iran.
ORCID-Profile: Somayeh Zeighami
Förderung
- Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences
Zitieren
APA
Siadat, H., Chitsaz, F., Zeighami, S., & Esmaeilzadeh, A. (2024). Accuracy of maxillary full‐arch digital impressions of tooth and implant models made by two intraoral scanners. Clinical and Experimental Dental Research, 10(2). https://doi.org/10.1002/cre2.857
Vancouver
Siadat H, Chitsaz F, Zeighami S, Esmaeilzadeh A. Accuracy of maxillary full‐arch digital impressions of tooth and implant models made by two intraoral scanners. Clinical and Experimental Dental Research. 2024;10(2). doi:10.1002/cre2.857
BibTeX
@article{Siadat2024,
author = {Siadat, Hakimeh and Chitsaz, Foujan and Zeighami, Somayeh and Esmaeilzadeh, Alireza},
title = {Accuracy of maxillary full‐arch digital impressions of tooth and implant models made by two intraoral scanners},
journal = {Clinical and Experimental Dental Research},
year = {2024},
volume = {10},
number = {2},
doi = {10.1002/cre2.857}
}
EUVIMED