Full‐Arch Digital Implant Impression Trueness: An in Vivo Study
Clinical Oral Implants Research · 2025-05 · 36 (5) · 640-649
DOI: 10.1111/clr.14411 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 31.01.2025. Verfasst von Vygandas Rutkūnas und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania. Hauptthemen laut MEDLINE: Dental Impression Technique, Dental Implants, Computer-Aided Design, Dental Arch. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Lithuanian Business Support Agency, Oral Reconstructive Foundation.
Abstract (Originalsprache)
Objectives
To evaluate the trueness of maxillary and mandibular full‐arch implant digital impressions with and without additional reference objects. Material and Methods Seventeen maxillary and 6 mandibular arches with four implants were randomly divided into a group with additional reference objects (wRO group, n = 12) and without them (woRO group, n = 11) and scanned with an intraoral scanner (IOS). For each jaw, the control model (CM) data was obtained to evaluate the deviations in the scan body positions in the wRO and woRO groups. CM and IOS data sets were imported into metrology software for distance and angle measurements between scan body pairs 1–2, 1–3, and 1–4. Unsigned values of distance and angle data differences between CM and IOS groups were used for further analysis.
Results
The highest statistically significant ( p < 0.05 ) differences between distance and angulation measurements of the maxilla and mandible were observed in the 1–4 scan body pair group (136 ± 95 μm, 0.95° ± 0.79°; 362 ± 233 μm, 2.22° ± 2.11°, respectively). Distance deviations of the mandible were higher in all scan body pair groups. The woRO group had higher distance and angulation unsigned trueness values than in the wRO group, especially in the 1–4 scan body pair (224 ± 183 μm, 1.77° ± 1.76°;169 ± 162 μm, and 0.83° ± 0.57°, respectively).
Conclusions
IOS for the full‐arch cases had statistically and clinically significant distance and angle deviations. Higher deviations were observed in the single mandibular scan body pair. The tendency of diminished distance and angular deviations with the utilization of the additional reference objects was observed, though these differences were not statistically significant.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania.
- Department of Periodontology, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania.
- Department of Restorative Dentistry, School of Dental Medicine, University of Washington, Seattle, Washington, USA.
- Kois Center, Seattle, Washington, USA.
- Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA.
- Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania.
ORCID-Profile: Marta Revilla-León
Förderung
- Lithuanian Business Support Agency
- Oral Reconstructive Foundation
Zitieren
APA
Rutkūnas, V., Kuleš, D., Revilla-León, M., Akulauskas, M., Auškalnis, L., & Gendvilienė, I. (2025). Full‐Arch Digital Implant Impression Trueness: An in Vivo Study. Clinical Oral Implants Research, 36(5), 640-649. https://doi.org/10.1111/clr.14411
Vancouver
Rutkūnas V, Kuleš D, Revilla-León M, Akulauskas M, Auškalnis L, Gendvilienė I. Full‐Arch Digital Implant Impression Trueness: An in Vivo Study. Clinical Oral Implants Research. 2025;36(5):640-649. doi:10.1111/clr.14411
BibTeX
@article{Rutknas2025,
author = {Rutkūnas, Vygandas and Kuleš, Daniel and Revilla-León, Marta and Akulauskas, Mykolas and Auškalnis, Liudas and Gendvilienė, Ieva},
title = {Full‐Arch Digital Implant Impression Trueness: An in Vivo Study},
journal = {Clinical Oral Implants Research},
year = {2025},
volume = {36},
number = {5},
pages = {640--649},
doi = {10.1111/clr.14411}
}
EUVIMED