EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Rapid Detection of Fumonisin B1 Using a Fluorescent Aptasensor with Plasmon-Modified Graphene Oxide as a Quencher

Yi Jiao, Xiaoqing Yang iD, Junping Hao, Yuhang Wen, Shanshan Wang, Jingbo Zhang iD, Hengchao E, Zhiyong Zhao, Jianhua Wang iD, Xianli Yang

Biosensors · 2026

DOI: 10.3390/bios16020133 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Yi Jiao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Agro-Food Standards and Testing Technology, Shanghai Academy of Agricultural Sciences, Shanghai 201403, China. Hauptthemen laut MEDLINE: Fumonisins, Graphite, Biosensing Techniques, Aptamers, Nucleotide. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shanghai Science and Technology Innovation Action Plan, National Natural Science Foundation of China, Distinguished Young Scholars Program of the Natural Science Foundation of Inner Mongolia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fumonisin B1 (FB1) is a secondary metabolite produced by Fusarium species, exhibiting strong toxicity and classified as a Group 2B carcinogen by the International Agency for Research on Cancer. It poses a significant threat to both human and animal health. Therefore, developing a simple and reliable method for FB1 detection and analysis is imperative. In this study, a biosensor based on nucleic acid aptamers was developed, utilizing plasma-modified graphene oxide (mGO) as a fluorescence quencher for FB1 detection. This system leverages the interaction between mGO and FAM-APT (a nucleic acid aptamer labeled with 5-carboxyfluorescein, FAM), achieving fluorescence quenching through fluorescence resonance energy transfer (FRET) under excitation at 490 nm and emission at 520 nm. In the presence of FB1, FAM-APT specifically binds to FB1 and dissociates from the mGO surface, resulting in fluorescence recovery. Quantitative detection of FB1 was achieved by measuring the differential fluorescence intensity. The biosensor demonstrated excellent linearity over a concentration range of 10 to 5 × 106 ng/L, with a detection limit (LOD) as low as 0.16 μg/L. Additionally, the sensor exhibited high specificity for FB1 among six common mycotoxins. In practical sample analysis, recovery rates ranged from 95.8% to 104.7% in corn samples and from 89.3% to 94.5% in rice samples. This aptamer-based biosensor features a simple structure, high sensitivity, and a wide detection range, providing important technical support for advancing mycotoxin research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FumonisinsGraphiteBiosensing TechniquesAptamers, NucleotideFluorescence Resonance Energy TransferLimit of DetectionFluorescent DyesFluorescent Chemosensor Compounds

Stichwörter der Autor:innen

aptamer sensorcold plasmafumonisin B1graphene oxiderapid detection

Substanzen

FumonisinsGraphitefumonisin B1Aptamers, Nucleotidegraphene oxideFluorescent DyesFluorescent Chemosensor Compounds

Autor:innen und Institutionen

  • Institute for Agro-Food Standards and Testing Technology, Shanghai Academy of Agricultural Sciences, Shanghai 201403, China.
  • College of Chemistry and Chemical Engineering, Mudanjiang Normal University, Mudanjiang 157012, China.
  • Weihai Municipal Hospital, Cheeloo College of Medicine, Shandong University, Weihai 264200, China.
  • School of Science, Inner Mongolia University of Science and Technology, Baotou 014010, China.
  • College of Plant Science and Technology, Huazhong Agricultural University, Wuhan 30070, China.

ORCID-Profile: Xiaoqing Yang, Jingbo Zhang, Jianhua Wang

Förderung

  • Shanghai Science and Technology Innovation Action Plan
  • National Natural Science Foundation of China
  • Distinguished Young Scholars Program of the Natural Science Foundation of Inner Mongolia
  • the Program for Young Talents in Science and Technology in Universities of Inner Mongolia Autonomous Region
  • the Fundamental Research Funds for Inner Mongolia University of Science and Technology
  • China Scholarship Council
  • Program for Young Talents in Science and Technology in Universities of Inner Mongolia Autonomous Region
  • Fundamental Research Funds for Inner Mongolia University of Science and Technology

Zitieren

APA

Jiao, Y., Yang, X., Hao, J., Wen, Y., Wang, S., Zhang, J., E, H., Zhao, Z., Wang, J., & Yang, X. (2026). Rapid Detection of Fumonisin B1 Using a Fluorescent Aptasensor with Plasmon-Modified Graphene Oxide as a Quencher. Biosensors. https://doi.org/10.3390/bios16020133

Vancouver

Jiao Y, Yang X, Hao J, Wen Y, Wang S, Zhang J, et al. Rapid Detection of Fumonisin B1 Using a Fluorescent Aptasensor with Plasmon-Modified Graphene Oxide as a Quencher. Biosensors. 2026. doi:10.3390/bios16020133

BibTeX
@article{Jiao2026,
  author = {Jiao, Yi and Yang, Xiaoqing and Hao, Junping and Wen, Yuhang and Wang, Shanshan and Zhang, Jingbo and E, Hengchao and Zhao, Zhiyong and Wang, Jianhua and Yang, Xianli},
  title = {Rapid Detection of Fumonisin B1 Using a Fluorescent Aptasensor with Plasmon-Modified Graphene Oxide as a Quencher},
  journal = {Biosensors},
  year = {2026},
  doi = {10.3390/bios16020133}
}
Kostenlos starten →