EUVIMEDEUVIMED entdecken
Crossref

FRET-driven fluorescent aptasensor for ultrasensitive low-density lipoprotein detection integration of sulfur-doped carbon nitride quantum dots and MXene-Gold nanocomposites

Guiyin Li, Cunhong Cen, Junan He, Wei He, Jincai Xie, Lingling Fan, Xiaohong Tan, Yong Huang

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026-02 · 347 · 126970

DOI: 10.1016/j.saa.2025.126970 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026-02. Verfasst von Guiyin Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Guangdong University of Petrochemical Technology, Guandu Road, Maoming, Guangdong 525000, People's Republic of China; State Key…. Hauptthemen laut MEDLINE: Quantum Dots, Fluorescence Resonance Energy Transfer, Gold, Aptamers, Nucleotide. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: National College Students Innovation and Entrepreneurship Training Program, Science and Technology Major Project of Guangxi, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Low-density lipoprotein (LDL) is a critical biomarker for cardiovascular disease (CVD) risk assessment. Accurate and sensitive monitoring of LDL levels in human serum is crucial for timely diagnosis, targeted intervention, and reduction of mortality. In this paper, we constructed a fluorescent aptamer sensor for LDL determination based on sulfur-doped graphitic carbon nitride quantum dots conjugated with LDL aptamer (S-g-CNQDs-LDLApt) as a fluorescence donor and MXene-supported gold nanoparticles (MXene-Au) as the energy acceptor, based on fluorescence resonance energy transfer (FRET) principle. The sensing mechanism relies on LDL concentration-dependent fluorescence recovery mediated by the disruption of FRET. Under optimal conditions, the fluorescent aptamer sensor exhibited a linear dynamic range of 20.0-100.0 μg/mL (regression equation: Y = 0.00874× - 0.07426, R2 = 0.9900), with a detection limit (LOD) of 0.343 μg/mL. In clinical serum samples, the relative standard deviations (RSD) ranged from 0.48 % to 2.64 %, confirming the sensor's reliability for LDL analysis in biological matrices. The proposed biosensor demonstrates great potential for clinical serum analysis, offering a novel paradigm for point-of-care CVD risk stratification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quantum DotsFluorescence Resonance Energy TransferGoldAptamers, NucleotideNanocompositesLipoproteins, LDLBiosensing TechniquesSulfurNitrilesGraphiteFluorescent DyesNitrogen CompoundsHumansLimit of DetectionReproducibility of ResultsNitritesTransition Elements

Stichwörter der Autor:innen

Fluorescence resonance energy transfer principleFluorescent aptamer sensorLow-density lipoprotein (LDL)MXene-AuS-g-CNQDs

Substanzen

GoldAptamers, NucleotideLipoproteins, LDLcyanogenSulfurNitrilesGraphitegraphitic carbon nitrideFluorescent DyesNitrogen Compounds

Autor:innen und Institutionen

  • College of Chemistry, Guangdong University of Petrochemical Technology, Guandu Road, Maoming, Guangdong 525000, People's Republic of China; State Key Laboratory of Targeting Oncology, National Center for International R…
  • College of Chemistry, Guangdong University of Petrochemical Technology, Guandu Road, Maoming, Guangdong 525000, People's Republic of China.
  • College of Chemistry, Guangdong University of Petrochemical Technology, Guandu Road, Maoming, Guangdong 525000, People's Republic of China. Electronic address: tanxiaohong2022@163.com.
  • State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-Targeting Theranostics, Guangxi Key Laboratory of Bio-Targeting Theranostics, Collaborative Innovation Center for Targeting T…

Förderung

  • National College Students Innovation and Entrepreneurship Training Program
  • Science and Technology Major Project of Guangxi
  • National Natural Science Foundation of China
  • National Major Science and Technology Projects of China
  • Guangdong University of Petrochemical Technology

Zitieren

APA

Li, G., Cen, C., He, J., He, W., Xie, J., Fan, L., Tan, X., & Huang, Y. (2026). FRET-driven fluorescent aptasensor for ultrasensitive low-density lipoprotein detection integration of sulfur-doped carbon nitride quantum dots and MXene-Gold nanocomposites. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 347, 126970. https://doi.org/10.1016/j.saa.2025.126970

Vancouver

Li G, Cen C, He J, He W, Xie J, Fan L, et al. FRET-driven fluorescent aptasensor for ultrasensitive low-density lipoprotein detection integration of sulfur-doped carbon nitride quantum dots and MXene-Gold nanocomposites. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026;347:126970. doi:10.1016/j.saa.2025.126970

BibTeX
@article{Li2026,
  author = {Li, Guiyin and Cen, Cunhong and He, Junan and He, Wei and Xie, Jincai and Fan, Lingling and Tan, Xiaohong and Huang, Yong},
  title = {FRET-driven fluorescent aptasensor for ultrasensitive low-density lipoprotein detection integration of sulfur-doped carbon nitride quantum dots and MXene-Gold nanocomposites},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2026},
  volume = {347},
  pages = {126970},
  doi = {10.1016/j.saa.2025.126970}
}
Kostenlos starten →