EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Pillararene-based fluorescence indicator displacement assays for the ratiometric and turn-on detection of ATP

Etelka Kiss, Dávid Mester, Dóra Hessz, Ervin Kovács, Krisztina László, Miklós Kubinyi

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2027

DOI: 10.1016/j.saa.2026.128536 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2027. Verfasst von Etelka Kiss und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Chemistry and Materials Science, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Econo…. Hauptthemen laut MEDLINE: Adenosine Triphosphate, Fluorescent Dyes, Quaternary Ammonium Compounds. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Research Development and Innovation Office, Nemzeti Kutatási Fejlesztési és Innovációs Hivatal, Nemzeti Kutatási, Fejlesztési és Innovaciós Alap.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For ATP detection, indicator displacement assays with multicationic macrocyclic hosts and anionic fluorescent dye guests represent an intuitive design strategy. However, such systems typically exhibit turn-off responses. For biological samples with strong background- and autofluorescence, ratiometric or turn-on signaling is preferred, which requires more sophisticated assay architectures. In the present work, the host-guest complexation of fluorescent pH indicator dye trisodium 8-hydroxypyrene-1,3,6-trisulfonic acid (HPTS) with a cationic ammonium-pillar[6]arene (AP6) was employed in the design of indicator displacement assays featuring two distinct detection modes for the fluorescent sensing of nucleotide ATP. In the first approach, AP6-assisted deprotonation of HPTS enabled the development of a colorimetric and a fluorescent ratiometric assay. In the second strategy, fluorescence turn-on sensing was achieved by exploiting the FRET-type quenching of HPTS fluorescence by AP6-modified reduced graphene oxide (rGO-AP6). Both sensing platforms demonstrated high selectivity toward ATP over structurally similar nucleotides and other biologically relevant anions, a broad dynamic range and a low limit of detection. The performance of the turn-on ATP sensor was validated in the complex biological matrix of human serum, demonstrating its applicability for practical bioanalytical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Adenosine TriphosphateFluorescent DyesQuaternary Ammonium CompoundsSpectrometry, FluorescenceFluorescence Resonance Energy TransferFluorescent Chemosensor CompoundsLimit of DetectionGraphiteHydrogen-Ion ConcentrationArylsulfonatesColorimetryHumans

Stichwörter der Autor:innen

Fluorescence indicator displacement (FID) assayFörster resonance energy transfer (FRET)HPTS (Pyranine)Nucleotide sensorReduced graphene oxideTurn-on fluorescent probe

Substanzen

Adenosine TriphosphateFluorescent DyesFluorescent Chemosensor CompoundsGraphitegraphene oxideArylsulfonatespyranineQuaternary Ammonium Compounds

Autor:innen und Institutionen

  • Department of Physical Chemistry and Materials Science, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem rkp. 3, H-1111 Budapest, Hungary; BrainVisionCenter Re…
  • Department of Physical Chemistry and Materials Science, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem rkp. 3, H-1111 Budapest, Hungary; MTA-BME Lendület Qua…
  • Department of Physical Chemistry and Materials Science, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem rkp. 3, H-1111 Budapest, Hungary.
  • BrainVisionCenter Research Institute, Liliom u. 43-45, H-1094 Budapest, Hungary; Institute of Materials and Environmental Chemistry, HUN-REN Research Centre for Natural Sciences, Budapest, Magyar tudósok körútja 2, H-11…
  • Department of Physical Chemistry and Materials Science, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem rkp. 3, H-1111 Budapest, Hungary. Electronic address:…

Förderung

  • National Research Development and Innovation Office
  • Nemzeti Kutatási Fejlesztési és Innovációs Hivatal
  • Nemzeti Kutatási, Fejlesztési és Innovaciós Alap
  • Hungarian Academy of Sciences

Zitieren

APA

Kiss, E., Mester, D., Hessz, D., Kovács, E., László, K., & Kubinyi, M. (2027). Pillararene-based fluorescence indicator displacement assays for the ratiometric and turn-on detection of ATP. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2026.128536

Vancouver

Kiss E, Mester D, Hessz D, Kovács E, László K, Kubinyi M. Pillararene-based fluorescence indicator displacement assays for the ratiometric and turn-on detection of ATP. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2027. doi:10.1016/j.saa.2026.128536

BibTeX
@article{Kiss2027,
  author = {Kiss, Etelka and Mester, Dávid and Hessz, Dóra and Kovács, Ervin and László, Krisztina and Kubinyi, Miklós},
  title = {Pillararene-based fluorescence indicator displacement assays for the ratiometric and turn-on detection of ATP},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2027},
  doi = {10.1016/j.saa.2026.128536}
}
Kostenlos starten →