FRET-triggered fluorescence switching: a g-CNQDs/Cu-TCPP “turn-on” aptasensor for ultrasensitive GP73 detection
Microchimica Acta · 2026
DOI: 10.1007/s00604-025-07808-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2026. Verfasst von Yu Zhou und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People's Republic of China. Hauptthemen laut MEDLINE: Fluorescence Resonance Energy Transfer, Aptamers, Nucleotide, Membrane Proteins, Biosensing Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Innovation Project of GUET Graduate Education, the National Nature Science Foundation of China, the Projects for Key Universities in Guangdong Province.
Abstract (Originalsprache)
Hepatocellular carcinoma (HCC) is one of the most lethal malignancies worldwide, and early diagnosis is crucial. Golgi protein 73 (GP73) has emerged as a promising serum biomarker for HCC. However, current detection methods often fail to meet routine screening requirements due to limitations in sensitivity and operational simplicity. To address these challenges, we have developed a novel fluorescent aptamer-based sensor for highly sensitive GP73 detection based on the fluorescence resonance energy transfer (FRET) mechanism between graphitic carbon nitride quantum dots (g-CNQDs) and a copper-based metal-organic framework (Cu-TCPP). g-CNQDs were covalently conjugated with a GP73-specific aptamer to serve as the fluorescent donor, while two-dimensional Cu-TCPP nanosheets acted as the efficient acceptors. Fluorescence was quenched upon donor-acceptor interaction via FRET. In the presence of GP73, aptamer-target binding disrupted FRET interaction, separating the donor from the acceptor and restoring fluorescence in a concentration-dependent manner. Under optimal conditions, the sensor exhibited excellent linearity over a concentration range 1.0-225.0 ng mL⁻¹, with a detection limit as low as 0.907 ng mL⁻¹. Recoveries for spiked human serum samples ranged from 95.96% to 103.85%, with relative standard deviations (RSDs) of 0.38%-5.48%. The developed aptamer sensor demonstrated excellent sensitivity, selectivity, and stability, providing a powerful tool for early HCC diagnosis and offering strong potential for real-time analytical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People's Republic of China.
- Department of Clinical Laboratory, The 924st Hospital of Chinese People's Liberation Army Joint Logistic Support Force, Guilin, Guangxi, 541002, China.
- College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong, 525000, People's Republic of China.
- Department of Clinical Laboratory, The 924st Hospital of Chinese People's Liberation Army Joint Logistic Support Force, Guilin, Guangxi, 541002, China. jiejingchen@126.com.
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People's Republic of China. dxljt@guet.edu.cn.
- College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong, 525000, People's Republic of China. liguiyin01@gdupt.edu.cn.
Förderung
- Innovation Project of GUET Graduate Education
- the National Nature Science Foundation of China
- the Projects for Key Universities in Guangdong Province
- Projects of Talents Recruitment of GDUPT
Zitieren
APA
Zhou, Y., Wu, R., Fan, L., Qui, P., Deng, X., Tan, X., Dong, S., Li, C., Chen, J., Liang, J., & Li, G. (2026). FRET-triggered fluorescence switching: a g-CNQDs/Cu-TCPP “turn-on” aptasensor for ultrasensitive GP73 detection. Microchimica Acta. https://doi.org/10.1007/s00604-025-07808-4
Vancouver
Zhou Y, Wu R, Fan L, Qui P, Deng X, Tan X, et al. FRET-triggered fluorescence switching: a g-CNQDs/Cu-TCPP “turn-on” aptasensor for ultrasensitive GP73 detection. Microchimica Acta. 2026. doi:10.1007/s00604-025-07808-4
BibTeX
@article{Zhou2026,
author = {Zhou, Yu and Wu, Runqiang and Fan, Lingling and Qui, Pengtao and Deng, Xiaohua and Tan, Xiaohong and Dong, Shuaikang and Li, Canru and Chen, Jiejing and Liang, Jintao and Li, Guiyin},
title = {FRET-triggered fluorescence switching: a g-CNQDs/Cu-TCPP “turn-on” aptasensor for ultrasensitive GP73 detection},
journal = {Microchimica Acta},
year = {2026},
doi = {10.1007/s00604-025-07808-4}
}
EUVIMED