EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Preliminary Study Using Wearable Near-Infrared Spectroscopy for Continuous Monitoring of Hemodynamics Through the Carotid Artery

Nisha Maheshwari iD, Alessandro Marone iD, Lokesh Sharma iD, Stephen Kim, Albert Favate, Andreas H Hielscher

Biosensors · 2025

DOI: 10.3390/bios15080549 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Nisha Maheshwari und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, 6 MetroTech Center, New York University Tandon School of Engineering, Brooklyn, NY 11201, USA. Hauptthemen laut MEDLINE: Carotid Arteries, Hemodynamics, Wearable Electronic Devices. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: New York University, NYU Future Labs, NYU Office of the Provost.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-invasive, continuous monitoring of carotid artery hemodynamics may provide valuable insights on cerebral blood perfusion (CBP). Near-infrared spectroscopy (NIRS) is a non-invasive modality that may be a good candidate for real-time carotid artery monitoring. We designed a wearable NIRS system to monitor the left and right radial and carotid arteries in 20 healthy subjects. The changes in total hemoglobin concentration (HbT) and tissue oxygen saturation (StO2) in all 80 arteries were continuously monitored in response to changes in oxygen supply. Wilcoxon non-parametric equivalence testing was used to compare changes in the radial (reference) and carotid arteries. The system-derived HbT and StO2 trends matched the expected physiological responses over time in the radial and carotid arteries. The mean peak-to-peak amplitude [uM] of HbT during sustained deep breathing was practically equivalent between the left radial (0.9 ± 0.8) and left carotid (1.6 ± 1.1) arteries (p = 0.01). The mean peak-to-peak amplitude [%] of StO2 was practically equivalent between the left radial (0.3 ± 0.2) and left carotid (0.3 ± 0.2) arteries (p < 0.001) and the right radial (0.4 ± 0.5) and right carotid (0.5 ± 0.4) arteries (p = 0.001). These findings indicate that NIRS may be a good option for monitoring the carotid arteries to track changes in CBP.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carotid ArteriesHemodynamicsWearable Electronic DevicesHumansSpectroscopy, Near-InfraredMaleAdultFemaleMonitoring, PhysiologicHemoglobins

Stichwörter der Autor:innen

Biophotonicscarotid arteryhemodynamicsnear-infrared spectroscopytissue oxygen saturation

Substanzen

Hemoglobins

Autor:innen und Institutionen

  • Department of Biomedical Engineering, 6 MetroTech Center, New York University Tandon School of Engineering, Brooklyn, NY 11201, USA.
  • CaroRhythm, Inc., 628 E 11th St, New York, NY 10009, USA.
  • Department of Vascular Neurology, New York University Grossman School of Medicine, 222 E 41st St Fl 10, New York, NY 10017, USA.

ORCID-Profile: Nisha Maheshwari, Alessandro Marone, Lokesh Sharma

Förderung

  • New York University
  • NYU Future Labs
  • NYU Office of the Provost

Zitieren

APA

Maheshwari, N., Marone, A., Sharma, L., Kim, S., Favate, A., & Hielscher, A. H. (2025). Preliminary Study Using Wearable Near-Infrared Spectroscopy for Continuous Monitoring of Hemodynamics Through the Carotid Artery. Biosensors. https://doi.org/10.3390/bios15080549

Vancouver

Maheshwari N, Marone A, Sharma L, Kim S, Favate A, Hielscher AH. Preliminary Study Using Wearable Near-Infrared Spectroscopy for Continuous Monitoring of Hemodynamics Through the Carotid Artery. Biosensors. 2025. doi:10.3390/bios15080549

BibTeX
@article{Maheshwari2025,
  author = {Maheshwari, Nisha and Marone, Alessandro and Sharma, Lokesh and Kim, Stephen and Favate, Albert and Hielscher, Andreas H},
  title = {Preliminary Study Using Wearable Near-Infrared Spectroscopy for Continuous Monitoring of Hemodynamics Through the Carotid Artery},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15080549}
}
Kostenlos starten →