Fachartikel in der Zeitschrift Advanced Science, 2024-03. Verfasst von Shuxing Xu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, 101400, China. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Stroke Rehabilitation, Electric Stimulation Therapy. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Key R & D Project from the Minister of Science and Technology.
Themen: Schlaganfall
Abstract (Originalsprache)
Innovative functional electrical stimulation has demonstrated effectiveness in enhancing daily walking and rehabilitating stroke patients with foot drop. However, its lack of precision in stimulating timing, individual adaptivity, and bilateral symmetry, resulted in diminished clinical efficacy. Therefore, a closed‐loop wearable device network of intrinsically controlled functional electrical stimulation (CI‐FES) system is proposed, which utilizes the personal surface myoelectricity, derived from the intrinsic neuro signal, as the switch to activate/deactivate the stimulation on the affected side. Simultaneously, it decodes the myoelectricity signal of the patient's healthy side to adjust the stimulation intensity, forming an intrinsically controlled loop with the inertial measurement units. With CI‐FES assistance, patients’ walking ability significantly improved, evidenced by the shift in ankle joint angle mean and variance from 105.53° and 28.84 to 102.81° and 17.71, and the oxyhemoglobin concentration tested by the functional near‐infrared spectroscopy. In long‐term CI‐FES‐assisted clinical testing, the discriminability in machine learning classification between patients and healthy individuals gradually decreased from 100% to 92.5%, suggesting a remarkable recovery tendency, further substantiated by performance on the functional movement scales. The developed CI‐FES system is crucial for contralateral‐hemiplegic stroke recovery, paving the way for future closed‐loop stimulation systems in stroke rehabilitation is anticipated.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, 101400, China.
- Center on Nanoenergy Research, School of Physical Science & Technology, Guangxi University, Nanning, 530004, China.
- School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing, 100049, China.
- Rehabilitation Medicine Department, The Second Affiliated Hospital of Nanchang University, Nanchang City, 330006, P. R. China.
- Department of Biomedical Engineering, College of Future Technology, Peking University, Beijing, 100871, China.
- Institute of Applied Nanotechnology, Jiaxing, Zhejiang, 314031, China.
ORCID-Profile: Wei Tang
Förderung
- National Natural Science Foundation of China
- National Key R & D Project from the Minister of Science and Technology
Zitieren
APA
Xu, S., Li, C., Wei, C., Kang, X., Shu, S., Liu, G., Xu, Z., Han, M., Luo, J., & Tang, W. (2024). Closed‐Loop Wearable Device Network of Intrinsically‐Controlled, Bilateral Coordinated Functional Electrical Stimulation for Stroke. Advanced Science, 11(17). https://doi.org/10.1002/advs.202304763
Vancouver
Xu S, Li C, Wei C, Kang X, Shu S, Liu G, et al. Closed‐Loop Wearable Device Network of Intrinsically‐Controlled, Bilateral Coordinated Functional Electrical Stimulation for Stroke. Advanced Science. 2024;11(17). doi:10.1002/advs.202304763
BibTeX
@article{Xu2024,
author = {Xu, Shuxing and Li, Chengyu and Wei, Conghui and Kang, Xinfang and Shu, Sheng and Liu, Guanlin and Xu, Zijie and Han, Mengdi and Luo, Jun and Tang, Wei},
title = {Closed‐Loop Wearable Device Network of Intrinsically‐Controlled, Bilateral Coordinated Functional Electrical Stimulation for Stroke},
journal = {Advanced Science},
year = {2024},
volume = {11},
number = {17},
doi = {10.1002/advs.202304763}
}
EUVIMED