EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Overarm Training Tolerance: A Pilot Study on the Use of Muscle Oxygen Saturation as a Biomarker

Bhargav Gorti, Connor Stephenson, Maia Sethi, KaiLi Gross, Mikaela Ramos iD, Dhruv Seshadri iD, Colin K Drummond iD

Sensors · 2024

DOI: 10.3390/s24144710 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Bhargav Gorti und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA. Hauptthemen laut MEDLINE: Biomarkers, Spectroscopy, Near-Infrared, Muscle, Skeletal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Case Western Reserve University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ulnar collateral ligament (UCL) tears occur due to the prolonged exposure and overworking of joint stresses, resulting in decreased strength in the flexion and extension of the elbow. Current rehabilitation approaches for UCL tears involve subjective assessments (pain scales) and objective measures such as monitoring joint angles and range of motion. The main goal of this study is to find out if using wearable near-infrared spectroscopy technology can help measure digital biomarkers like muscle oxygen levels and heart rate. These measurements could then be applied to athletes who have been injured. Specifically, measuring muscle oxygen levels will help us understand how well the muscles are using oxygen. This can indicate improvements in how the muscles are healing and growing new blood vessels after reconstructive surgery. Previous research studies demonstrated that there remains an unmet clinical need to measure biomarkers to provide continuous, internal data on muscle physiology during the rehabilitation process. This study’s findings can benefit team physicians, sports scientists, athletic trainers, and athletes in the identification of biomarkers to assist in clinical decisions for optimizing training regimens for athletes that perform overarm movements; the research suggests pathways for possible earlier detection, and thus earlier intervention for injury prevention.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BiomarkersSpectroscopy, Near-InfraredMuscle, SkeletalHumansPilot ProjectsMaleOxygen SaturationAdultOxygenFemaleWearable Electronic DevicesYoung AdultArmRange of Motion, Articular

Stichwörter der Autor:innen

clinical trialdigital biomarkersmuscle physiologyoverarm movementspilot studyrehabilitationtraining regimenulnar collateral ligamentwearables

Substanzen

BiomarkersOxygen

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.
  • Department of Biomedical Engineering, Lehigh University, Bethlehem, PA 18015, USA.

ORCID-Profile: Mikaela Ramos, Dhruv Seshadri, Colin K Drummond

Förderung

  • Case Western Reserve University

Zitieren

APA

Gorti, B., Stephenson, C., Sethi, M., Gross, K., Ramos, M., Seshadri, D., & Drummond, C. K. (2024). Overarm Training Tolerance: A Pilot Study on the Use of Muscle Oxygen Saturation as a Biomarker. Sensors. https://doi.org/10.3390/s24144710

Vancouver

Gorti B, Stephenson C, Sethi M, Gross K, Ramos M, Seshadri D, et al. Overarm Training Tolerance: A Pilot Study on the Use of Muscle Oxygen Saturation as a Biomarker. Sensors. 2024. doi:10.3390/s24144710

BibTeX
@article{Gorti2024,
  author = {Gorti, Bhargav and Stephenson, Connor and Sethi, Maia and Gross, KaiLi and Ramos, Mikaela and Seshadri, Dhruv and Drummond, Colin K},
  title = {Overarm Training Tolerance: A Pilot Study on the Use of Muscle Oxygen Saturation as a Biomarker},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24144710}
}
Kostenlos starten →