A High‐Accuracy and Easy‐Use Differential Diagnosis Method of Bipolar Disorder Depressive Phase and Major Depressive Disorder Using a Wearable Near‐Infrared Spectroscopy
Bipolar Disorders · 2026
DOI: 10.1111/bdi.70089 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bipolar Disorders, 2026. Verfasst von Yuji Sasaki und 3 weiteren Autor:innen. Beteiligte Einrichtung: Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan. Hauptthemen laut MEDLINE: Major Depressive Disorder, Bipolar Disorder, Wearable Electronic Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objectives
Although conventional multichannel near‐infrared spectroscopy (cNIRS) has been reported to be useful in differentiating bipolar disorder depressive phase (BDD) from major depressive disorder (MDD), its utilization in real clinical practice remains limited. The objective of this study was to evaluate the performance of wearable NIRS (wNIRS), which is cheaper to install and easier to use than cNIRS, in differentiating between BDD and MDD, and to propose an optimal index for wNIRS.
Methods
The subjects were 16 BDD patients, 16 MDD patients, and 16 healthy controls. Changes in the total hemoglobin signal (Δ[total‐Hb]) in the bilateral frontal cortex during a 60 s verbal fluency task (VFT) were measured using the HOT‐2000, a wNIRS capable of reducing noise from skin blood flow. In addition to evaluating the discriminative performance of the integral and centroid values proposed in previous studies, the ratio of the mean values of the Δ[total‐Hb] during the first 20 s and subsequent 40 s (20–40 ratio) during the VFT was also employed and assessed.
Results
Only the 20–40 ratio showed significant differences between BDD and MDD, whereas the integral and centroid values did not. Using a cut‐off value of 2.00 for the 20–40 ratio, the sensitivity and specificity of the BDD diagnosis were 100% and 93.4%, respectively.
Conclusions
The wNIRS measurements and the 20–40 ratio of the Δ[total‐Hb] in the forehead area enabled more accurate differentiation between MDD and BDD than the conventional analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
- Creative Design & Data Science Center, Akita International University, Akita, Japan.
ORCID-Profile: Koichi Ishizu
Zitieren
APA
Sasaki, Y., Ishizu, K., Seiyama, A., & Sugimoto, N. (2026). A High‐Accuracy and Easy‐Use Differential Diagnosis Method of Bipolar Disorder Depressive Phase and Major Depressive Disorder Using a Wearable Near‐Infrared Spectroscopy. Bipolar Disorders. https://doi.org/10.1111/bdi.70089
Vancouver
Sasaki Y, Ishizu K, Seiyama A, Sugimoto N. A High‐Accuracy and Easy‐Use Differential Diagnosis Method of Bipolar Disorder Depressive Phase and Major Depressive Disorder Using a Wearable Near‐Infrared Spectroscopy. Bipolar Disorders. 2026. doi:10.1111/bdi.70089
BibTeX
@article{Sasaki2026,
author = {Sasaki, Yuji and Ishizu, Koichi and Seiyama, Akitoshi and Sugimoto, Naozo},
title = {A High‐Accuracy and Easy‐Use Differential Diagnosis Method of Bipolar Disorder Depressive Phase and Major Depressive Disorder Using a Wearable Near‐Infrared Spectroscopy},
journal = {Bipolar Disorders},
year = {2026},
doi = {10.1111/bdi.70089}
}
EUVIMED