EUVIMEDEUVIMED entdecken
Open Access

The sensitivity of MIPs of 3D contrast-enhanced VIBE T1-weighted imaging for the detection of small brain metastases (≤ 5 mm) on 1.5 tesla MRI

Marco Parillo iD, Daniele Vertulli, Federica Vaccarino, Carlo Augusto Mallio, Bruno Beomonte Zobel, Carlo Cosimo Quattrocchi

The Neuroradiology Journal · 2024

DOI: 10.1177/19714009241260802 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Neuroradiology Journal, 2024. Verfasst von Marco Parillo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, Rome, Italy. Hauptthemen laut MEDLINE: Brain Neoplasms, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Contrast Media. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate whether the use of Maximum Intensity Projection (MIP) images derived from contrast-enhanced 3D-T1-weighted volumetric interpolated breath-hold examination (VIBE) would allow more sensitive detection of small (≤5 mm) brain metastases (BM) compared with source as well as 2D-T1-weighted spin-echo (SE) images.

Methods

We performed a single center retrospective study on subjects with BM who underwent 1.5 tesla brain magnetic resonance imaging. Two readers counted the number of small BM for each of the seven sets of contrast-enhanced images created: axial 2D-T1-weighted SE, 3D-T1-weighted VIBE, 2.5 mm-thick-MIP T1-weighted VIBE, and 5 mm-thick-MIP T1-weighted VIBE; sagittal 3D-T1-weighted VIBE, 2.5 mm-thick-MIP T1-weighted VIBE, and 5 mm-thick-MIP T1-weighted VIBE. Total number of lesions detected on each image type was compared. Sensitivity, the average rates of false negatives and false positives, and the mean discrepancy were evaluated.

Results

A total of 403 small BM were identified in 49 patients. Significant differences were found: in the number of true positives and false negatives between the axial 2D-T1-weighted SE sequence and all other imaging techniques; in the number of false positives between the axial 2D-T1-weighted SE and the axial 3D-T1-weighted VIBE sequences. The two image types that combined offered the highest sensitivity were 2D-T1-weighted SE and axial 2.5 mm-thick-MIP T1-weighted VIBE. The axial 2D-T1-weighted SE sequence differed significantly in sensitivity from all other sequences.

Conclusion

MIP images did not show a significant difference in sensitivity for the detection of small BM compared with native images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Brain NeoplasmsMagnetic Resonance ImagingImaging, Three-DimensionalContrast MediaSensitivity and SpecificityHumansFemaleMaleMiddle AgedRetrospective StudiesAgedAdultAged, 80 and overBreath HoldingImage Enhancement

Stichwörter der Autor:innen

Braincentral nervous system neoplasmsmagnetic resonance imagingmaximum intensity projectionneoplasm metastasisradiologyvolumetric interpolated breath-hold examination

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, Rome, Italy.
  • Research Unit of Diagnostic Imaging and Interventional Radiology, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, Rome, Italy.
  • Centre for Medical Sciences-CISMed, University of Trento, Italy.

ORCID-Profile: Marco Parillo

Zitieren

APA

Parillo, M., Vertulli, D., Vaccarino, F., Mallio, C. A., Beomonte Zobel, B., & Quattrocchi, C. C. (2024). The sensitivity of MIPs of 3D contrast-enhanced VIBE T1-weighted imaging for the detection of small brain metastases (≤ 5 mm) on 1.5 tesla MRI. The Neuroradiology Journal. https://doi.org/10.1177/19714009241260802

Vancouver

Parillo M, Vertulli D, Vaccarino F, Mallio CA, Beomonte Zobel B, Quattrocchi CC. The sensitivity of MIPs of 3D contrast-enhanced VIBE T1-weighted imaging for the detection of small brain metastases (≤ 5 mm) on 1.5 tesla MRI. The Neuroradiology Journal. 2024. doi:10.1177/19714009241260802

BibTeX
@article{Parillo2024,
  author = {Parillo, Marco and Vertulli, Daniele and Vaccarino, Federica and Mallio, Carlo Augusto and Beomonte Zobel, Bruno and Quattrocchi, Carlo Cosimo},
  title = {The sensitivity of MIPs of 3D contrast-enhanced VIBE T1-weighted imaging for the detection of small brain metastases (≤ 5 mm) on 1.5 tesla MRI},
  journal = {The Neuroradiology Journal},
  year = {2024},
  doi = {10.1177/19714009241260802}
}
Kostenlos starten →