EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

High resolution-dynamic characterization of cardiac masses: radio-frequency spoiled 3D gradient echo sequence

Elif Peker iD, Sena Ünal, Ruhi Erdem Ergüden, Nil Sezer Yılmazer Zorlu, Sena Bozer Uludağ

British Journal of Radiology · 2025

DOI: 10.1093/bjr/tqaf093 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Elif Peker und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Department of Radiology, Ankara University. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Imaging, Heart Neoplasms, Thrombosis. Die Arbeit nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Volumetric interpolated breath-hold examination (VIBE) sequence is a radio-frequency-spoiled gradient echo sequence that is mostly used in the evaluation of soft tissues, allows dynamic high-resolution images to be taken in 30 seconds of breath-holding time in MRI, and is used to create 3D images. In this study, we aimed to determine the detectability of cardiac masses and thrombi and their differentiation from the blood pool with the T1 VIBE imaging method.

Methods

Precontrast, early and late postcontrast VIBE images were evaluated. Lesion contours were drawn with a free-hand regìon of ìnterest (ROI) in the phase in which the lesion was better depicted. All ROIs were placed in the phase where the lesion appeared best and then copied to other phases.

Results

Sìgnal to noìse ratìo (SNR) was calculated as SI/SD of background intensity, CNR was calculated as SNR thrombus-SNR myocardium and SNR thrombus-SNR blood pool. SNR and CNR values of thrombus, blood pool, and myocardium measured at maps and contrast-enhanced images were compared with each other.

Conclusions

There are many sequences used routinely to detect cardiac masses and thrombi. Many of these techniques require long acquisition time. With the VIBE sequence, precontrast, arterial, and venous images of the lesion can be obtained quickly. Although the SNR and CNR values obtained with VIBE images are lower than those with routine post-contrast images, our study can be considered a preliminary study for future studies to evaluate dynamic images. Advances in knowledge For our knowledge, this is the first paper written on the visual assessment of cardiac masses on VIBE images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMagnetic Resonance ImagingHeart NeoplasmsThrombosisHumansMaleFemaleMiddle AgedSignal-To-Noise RatioAdultContrast MediaBreath HoldingAged

Stichwörter der Autor:innen

CNRSNRVIBEcardiac MRIthrombus

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Faculty of Medicine, Department of Radiology, Ankara University.

ORCID-Profile: Elif Peker

Zitieren

APA

Peker, E., Ünal, S., Ergüden, R. E., Yılmazer Zorlu, N. S., & Bozer Uludağ, S. (2025). High resolution-dynamic characterization of cardiac masses: radio-frequency spoiled 3D gradient echo sequence. British Journal of Radiology. https://doi.org/10.1093/bjr/tqaf093

Vancouver

Peker E, Ünal S, Ergüden RE, Yılmazer Zorlu NS, Bozer Uludağ S. High resolution-dynamic characterization of cardiac masses: radio-frequency spoiled 3D gradient echo sequence. British Journal of Radiology. 2025. doi:10.1093/bjr/tqaf093

BibTeX
@article{Peker2025,
  author = {Peker, Elif and Ünal, Sena and Ergüden, Ruhi Erdem and Yılmazer Zorlu, Nil Sezer and Bozer Uludağ, Sena},
  title = {High resolution-dynamic characterization of cardiac masses: radio-frequency spoiled 3D gradient echo sequence},
  journal = {British Journal of Radiology},
  year = {2025},
  doi = {10.1093/bjr/tqaf093}
}
Kostenlos starten →