EUVIMEDEUVIMED entdecken
Open Access

Comparative evaluation of zoomed and parallel diffusion-weighted imaging: A phantom study

Akiyoshi Iwase, Yasuo Takatsu iD, Naoki Ohno, Azusa Kitao, Tosiaki Miyati iD

Journal of Clinical Imaging Science · 10.08.2026 · 16 · 30

DOI: 10.25259/jcis_92_2025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Imaging Science, online erschienen am 10.08.2026. Verfasst von Akiyoshi Iwase und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Single-shot echo-planar imaging sequences with parallel imaging are widely used for diffusion-weighted imaging (DWI). However, when small fields of view and higher phase-encoding reduction ratios (PRs) are applied, image quality may deteriorate because of imperfections in the unfolding process of parallel imaging. Previous studies have suggested that Zoomed DWI (Zoom-DWI) may address this limitation. Therefore, we compared Zoom-DWI with parallel DWI (Parallel-DWI) across different PRs to evaluate image quality. Material and Methods: Zoom-DWI and Parallel-DWI were performed using identical acquisition times and imaging parameters at different PRs. Signal-to-noise ratio (SNR), image uniformity, slice thickness, spatial resolution, and image distortion were evaluated.

Results

At a PR of 66.6%, the SNR of Zoom-DWI was approximately 1.4–3.3-fold higher than that of Parallel-DWI at the image center, where reconstruction errors in parallel imaging become more pronounced as PR increases. Image uniformity was also higher in Zoom-DWI than in Parallel-DWI, and the difference increased by approximately 41.0% at a PR of 66.6%. Slice thickness, spatial resolution, and image distortion were comparable between the two methods.

Conclusion

In this phantom study, Zoom-DWI demonstrated higher SNR and greater image uniformity than Parallel-DWI, particularly at higher PRs and in the central image region.

Schlagwörter

Stichwörter der Autor:innen

Image uniformityParallel imagingPhantom studySignal-to-noise ratioZoomed diffusion-weighted imaging

Autor:innen und Institutionen

  • Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan.
  • Department of Molecular Imaging, Clinical Collaboration Unit, School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.

ORCID-Profile: Yasuo Takatsu, Tosiaki Miyati

Zitieren

APA

Iwase, A., Takatsu, Y., Ohno, N., Kitao, A., & Miyati, T. (2026). Comparative evaluation of zoomed and parallel diffusion-weighted imaging: A phantom study. Journal of Clinical Imaging Science, 16, 30. https://doi.org/10.25259/jcis_92_2025

Vancouver

Iwase A, Takatsu Y, Ohno N, Kitao A, Miyati T. Comparative evaluation of zoomed and parallel diffusion-weighted imaging: A phantom study. Journal of Clinical Imaging Science. 2026;16:30. doi:10.25259/jcis_92_2025

BibTeX
@article{Iwase2026,
  author = {Iwase, Akiyoshi and Takatsu, Yasuo and Ohno, Naoki and Kitao, Azusa and Miyati, Tosiaki},
  title = {Comparative evaluation of zoomed and parallel diffusion-weighted imaging: A phantom study},
  journal = {Journal of Clinical Imaging Science},
  year = {2026},
  volume = {16},
  pages = {30},
  doi = {10.25259/jcis_92_2025}
}
Kostenlos starten →