EUVIMEDEUVIMED entdecken
Crossref

Improved diffusion-weighted imaging of the prostate: Comparison of readout-segmented and zoomed single-shot imaging

M Klingebiel, E Weiland, M Boschheidgen, T Ullrich, C Arsov, J P Radtke, T Benkert, M Nickel, R Strecker, H J Wittsack, P Albers, G Antoch und 1 weitere

Magnetic Resonance Imaging · 2023-05 · 98 · 55-61

DOI: 10.1016/j.mri.2023.01.010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2023-05. Verfasst von M Klingebiel und 12 weiteren Autor:innen. Beteiligte Einrichtung: University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, D-40225 Dusseldorf, Germany. Electronic address: maxim…. Hauptthemen laut MEDLINE: Prostate, Echo-Planar Imaging. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Diffusion weighted imaging (DWI) is the most important sequence for detection and grading prostate cancer (PCa), but it is considerably prone to artifacts. New approaches like zoomed single-shot imaging (z-EPI) with advanced image processing or multi-shot readout segmentation (rs-EPI) try to improve DWI quality. This study evaluates objective and subjective image quality (IQ) of rs-EPI and z-EPI with and without advanced processing. MATERIALS AND METHODS: Fifty-six consecutive patients (67 ± 8 years; median PSA 8.3 ng/ml) with mp-MRI performed at 3 Tesla between February and October 2019 and subsequently verified PCa by targeted plus systematic MRI/US-fusion biopsy were included in this retrospective single center cohort study. Rs-EPI and z-EPI were prospectively acquired in every patient. Signal intensities (SI) of PCa and benign tissue in ADC, b1000, and calculated high b-value images were analyzed. Endpoints were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), PCa contrast intensity (CI), and subjective IQ on a 5-point scale evaluated by three blinded readers. Wilcoxon signed rank test, Friedman test and Cohen's kappa coefficient was calculated. RESULTS: SNR, CNR, and PCa CI of z-EPI with and without advanced processing was superior to rs-EPI (p < 0.01), whereas no significant differences were observed between z-EPI with and without advanced processing. Subjective IQ was significantly higher for z-EPI with advanced processing compared rs-EPI for ADC, b1000, and calculated high b-values (p < 0.01). Compared to z-EPI without advanced processing, z-EPI with advanced processing was superior for ADC and calculated high b-values (p < 0.01), but no significant differences were shown for b1000 images. CONCLUSIONS: Z-EPI with and without advanced processing was superior to rs-EPI regarding objective imaging parameters and z-EPI with advanced processing was superior to rs-EPI regarding subjective imaging parameters for the detection of PCa.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProstateEcho-Planar ImagingMaleHumansRetrospective StudiesCohort StudiesReproducibility of ResultsDiffusion Magnetic Resonance Imaging

Stichwörter der Autor:innen

DiagnosticDiffusion weighted MRIImagingMagnetic resonance imagingProstate cancer

Autor:innen und Institutionen

  • University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, D-40225 Dusseldorf, Germany. Electronic address: maximilian.klingebiel@med.uni-duesseldorf.de.
  • MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany. Electronic address: elisabeth.weiland@siemens-healthineers.com.
  • University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, D-40225 Dusseldorf, Germany. Electronic address: matthias.boschheidgen@med.uni-duesseldorf.de.
  • University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, D-40225 Dusseldorf, Germany. Electronic address: tim.ullrich@med.uni-duesseldorf.de.
  • University Dusseldorf, Medical Faculty, Department of Urology, D-40225 Dusseldorf, Germany. Electronic address: Christian.Arsov@sk-mg.de.
  • University Dusseldorf, Medical Faculty, Department of Urology, D-40225 Dusseldorf, Germany. Electronic address: JanPhilipp.radtke@med.uni-duesseldorf.de.

Zitieren

APA

Klingebiel, M., Weiland, E., Boschheidgen, M., Ullrich, T., Arsov, C., Radtke, J. P., Benkert, T., Nickel, M., Strecker, R., Wittsack, H. J., Albers, P., Antoch, G., & Schimmöller, L. (2023). Improved diffusion-weighted imaging of the prostate: Comparison of readout-segmented and zoomed single-shot imaging. Magnetic Resonance Imaging, 98, 55-61. https://doi.org/10.1016/j.mri.2023.01.010

Vancouver

Klingebiel M, Weiland E, Boschheidgen M, Ullrich T, Arsov C, Radtke JP, et al. Improved diffusion-weighted imaging of the prostate: Comparison of readout-segmented and zoomed single-shot imaging. Magnetic Resonance Imaging. 2023;98:55-61. doi:10.1016/j.mri.2023.01.010

BibTeX
@article{Klingebiel2023,
  author = {Klingebiel, M and Weiland, E and Boschheidgen, M and Ullrich, T and Arsov, C and Radtke, J P and Benkert, T and Nickel, M and Strecker, R and Wittsack, H J and Albers, P and Antoch, G and Schimmöller, L},
  title = {Improved diffusion-weighted imaging of the prostate: Comparison of readout-segmented and zoomed single-shot imaging},
  journal = {Magnetic Resonance Imaging},
  year = {2023},
  volume = {98},
  pages = {55--61},
  doi = {10.1016/j.mri.2023.01.010}
}
Kostenlos starten →