Multi-institution longitudinal apparent diffusion coefficient measurements in a diffusion weighted imaging phantom at room temperature
Physics and Imaging in Radiation Oncology · 2025-07 · 35 · 100814
DOI: 10.1016/j.phro.2025.100814 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics and Imaging in Radiation Oncology, 2025-07. Verfasst von Chris Moore und 11 weiteren Autor:innen. Beteiligte Einrichtung: Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cancer Research UK Manchester Centre, Royal College of Radiologists, Manchester Biomedical Research Centre.
Abstract (Originalsprache)
Background and purpose: This work contributes to technical validation of apparent diffusion coefficient (ADC) as a biomarker of cancer. The aim was to evaluate ADC accuracy, random error, short-term and long-term repeatability and reproducibility, across multiple institutions using a room temperature phantom. Materials and methods: ADC measurements were made in a travelling room temperature diffusion weighted imaging (DWI) phantom on six scanners at four UK institutions over 18 months at six-month intervals. ADC bias measurements were calculated as the difference between measured and temperature corrected ground-truth ADC values and used to calculate mean ADC bias, isocentre ADC error estimate, short- and long-term intra-scanner repeatability as per the Quantitative Imaging Biomarkers Alliance (QIBA) DWI profiles, and inter-scanner reproducibility by calculating the 95 % limits of agreement for all ADC bias measurements. Results: The use of a room-temperature phantom with a magnetic resonance (MR) readable thermometer enabled ADC measurements without ice-water setup, considerably simplifying logistics with respect to multi-institution ADC quality assurance. Mean ADC bias across all scanners and sessions was
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK.
- Division of Cancer Sciences, The University of Manchester, Manchester, UK.
- Medical Physics Department, University Hospitals of Leicester NHS Trust, Leicester, UK.
- Department of Medical Physics, University Hospital Southampton NHS Foundation Trust, Southampton, UK.
- Department of Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
- MR Physics, Sheffield Teaching Hospital NHS Foundation Trust, Sheffield, UK.
Förderung
- Cancer Research UK Manchester Centre
- Royal College of Radiologists
- Manchester Biomedical Research Centre
Zitieren
APA
Moore, C., Bull, C., Darekar, A., Wilson, D., Goodall, A., Manoharan, P., Hoskin, P., van Herk, M., Buckley, D. L., McHugh, D. J., Datta, A., & Dubec, M. J. (2025). Multi-institution longitudinal apparent diffusion coefficient measurements in a diffusion weighted imaging phantom at room temperature. Physics and Imaging in Radiation Oncology, 35, 100814. https://doi.org/10.1016/j.phro.2025.100814
Vancouver
Moore C, Bull C, Darekar A, Wilson D, Goodall A, Manoharan P, et al. Multi-institution longitudinal apparent diffusion coefficient measurements in a diffusion weighted imaging phantom at room temperature. Physics and Imaging in Radiation Oncology. 2025;35:100814. doi:10.1016/j.phro.2025.100814
BibTeX
@article{Moore2025,
author = {Moore, Chris and Bull, Charlotte and Darekar, Angela and Wilson, Daniel and Goodall, Alex and Manoharan, Prakash and Hoskin, Peter and van Herk, Marcel and Buckley, David L and McHugh, Damien J and Datta, Anubhav and Dubec, Michael J},
title = {Multi-institution longitudinal apparent diffusion coefficient measurements in a diffusion weighted imaging phantom at room temperature},
journal = {Physics and Imaging in Radiation Oncology},
year = {2025},
volume = {35},
pages = {100814},
doi = {10.1016/j.phro.2025.100814}
}
EUVIMED