EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Effects of simulated gastric acid on the optical properties of CAD/CAM glass-ceramics

Isil Buyukhatipoglu, Derya Evlice, Fatih Sari, Asli Secilmis

Vojnosanitetski pregled · 2026 · (00) · 63-63

DOI: 10.2298/vsp251017063b ↗

Kurz gefasst

Fachartikel in der Zeitschrift Vojnosanitetski pregled, 2026. Verfasst von Isil Buyukhatipoglu und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Aim. The influence of glazing and polishing procedures on surface changes in contemporary computer-aided design (CAD) and computer-aided manufacturing (CAM) - CAD/CAM glass-ceramics during exposure to simulated gastric acid remains unclear. The aim of this study was to investigate the effects of simulated gastric acid on the optical properties of glazed or polished glass-ceramic materials based on lithium disilicate, advanced lithium disilicate, and zirconia-reinforced lithium silicate.

Methods

The specimens were divided into six experimental groups according to the ceramic material and surface-finishing procedure recommended by the manufacturers: CEREC Tessera™-glazed (CTG), CEREC Tessera™-polished (CTP), IPS e.max® CAD-glazed (IPSG), IPS e.max® CAD-polished (IPSP), VITA Suprinity®-glazed (VSG), and VITA Suprinity®-polished (VSP), with 10 specimens allocated to each group (n = 10). To simulate gastric conditions, the samples were immersed in hydrochloric acid (HCl, 0.06 M; pH 1.2) and incubated at 37 °C for 96 hrs. Before and after acid immersion, perceptual lightness (L*), red-green (a*), and yellow-blue (b*) coordinate values were recorded using a calibrated digital spectrophotometer. Color difference (ΔE₀₀) and translucency parameter (TP₀₀) were subsequently calculated using the CIEDE2000 formula. The data were analyzed using the Kruskal-Wallis and Wilcoxon signed-rank tests at a significance level of p < 0.05.

Results

Acid immersion did not significantly affect the ΔE₀₀ of the tested CAD/CAM glass-ceramics (p > 0.05). In contrast, TP₀₀ was significantly influenced by both ceramic material and surface-finishing protocol. Significant reductions in TP₀₀ values were observed in the CTG, CTP, and IPSG groups after acid immersion, whereas IPSP, VSG, and VSP showed no significant changes. Analysis of ΔTP₀₀ revealed significant intergroup differences, with the highest median values observed in the IPSG, CTP, and VSP groups and the lowest in IPSP.

Conclusion

Within the limitations of this in vitro study, no significant differences in ΔE₀₀ were observed among the tested experimental groups following exposure to simulated gastric acid. However, TP₀₀ appeared to be more sensitive to the acid challenge than color, and the changes varied according to the tested ceramic material and surface-finishing protocol.

Zitieren

APA

Buyukhatipoglu, I., Evlice, D., Sari, F., & Secilmis, A. (2026). Effects of simulated gastric acid on the optical properties of CAD/CAM glass-ceramics. Vojnosanitetski pregled, 63-63. https://doi.org/10.2298/vsp251017063b

Vancouver

Buyukhatipoglu I, Evlice D, Sari F, Secilmis A. Effects of simulated gastric acid on the optical properties of CAD/CAM glass-ceramics. Vojnosanitetski pregled. 2026:63-63. doi:10.2298/vsp251017063b

BibTeX
@article{Buyukhatipoglu2026,
  author = {Buyukhatipoglu, Isil and Evlice, Derya and Sari, Fatih and Secilmis, Asli},
  title = {Effects of simulated gastric acid on the optical properties of CAD/CAM glass-ceramics},
  journal = {Vojnosanitetski pregled},
  year = {2026},
  number = {00},
  pages = {63--63},
  doi = {10.2298/vsp251017063b}
}
Kostenlos starten →