EUVIMEDEUVIMED entdecken
Crossref

Wear behavior of materials for fixed dental prostheses

Kantaro Kojima, Takuya Kihara, Tomoko Ikawa, Yuko Shigeta, Takumi Ogawa

Journal of Prosthodontic Research · 2026

DOI: 10.2186/jpr.jpr_d_25_00037 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontic Research, 2026. Verfasst von Kantaro Kojima und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fixed Prosthodontics, School of Dental Medicine, Tsurumi University, Yokohama, Japan. Hauptthemen laut MEDLINE: Materials Testing, Dental Restoration Wear, Dental Materials, Dental Prosthesis. Die Arbeit nennt 47 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study evaluated the wear behavior of dental materials for definitive fixed prostheses, including computer-aided design (CAD)- and manufacturing (CAM) composite resins, polyether-ether-ketone (PEEK), Ag-Pd-Au alloys, titanium, and zirconia, under standardized experimental conditions. METHODS: Three CAD-CAM-produced composite resins (HC, HCH, and CS), PEEK (SPE), Ag-Pd-Au alloys (CW), pure titanium class II (TJ), and zirconia (ZL) were tested. Two-body wear tests were conducted using an abrasion-testing machine under wet conditions using stainless-steel styluses as antagonists. Wear traces were examined using laser confocal scanning microscopy and scanning electron microscopy (SEM). Wear depths and heights were analyzed by one-way analysis of variance with Tukey's multiple comparison test. RESULTS: The wear depths of CS and TJ were significantly greater than those of the other materials (P < 0.05), whereas ZL exhibited the lowest wear depth. No significant differences were found among HC, HCH, SPE, and CW. The stylus opposing the SPE exhibited the smallest wear height, whereas TJ caused the most antagonist wear. SEM revealed distinct wear mechanisms, including adhesive and abrasive wear, depending on the material. CONCLUSIONS: The SPE and CW showed similar wear behavior. CAD/CAM composite resins demonstrated variable wear rates, which was likely attributable to variations in the composition and morphology of the constituent fillers. The TJ exhibited excessive antagonist wear, suggesting the need for improved tribological properties. These findings provide guidance for selecting materials that preserve occlusion and prevent excessive wear.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Materials TestingDental Restoration WearDental MaterialsDental ProsthesisZirconiumComputer-Aided DesignKetonesTitaniumMicroscopy, Electron, ScanningComposite ResinsPolyethylene GlycolsBenzophenonesPolyether CompoundsGold AlloysSurface PropertiesMicroscopy, ConfocalSilverPolymers

Stichwörter der Autor:innen

CAD-CAMPEEKTribological behaviorWearZirconia

Substanzen

Zirconiumzirconium oxideKetonesDental MaterialsTitaniumComposite ResinsPolyethylene GlycolsBenzophenonesPolyether CompoundsGold Alloys

Autor:innen und Institutionen

  • Department of Fixed Prosthodontics, School of Dental Medicine, Tsurumi University, Yokohama, Japan.

Zitieren

APA

Kojima, K., Kihara, T., Ikawa, T., Shigeta, Y., & Ogawa, T. (2026). Wear behavior of materials for fixed dental prostheses. Journal of Prosthodontic Research. https://doi.org/10.2186/jpr.jpr_d_25_00037

Vancouver

Kojima K, Kihara T, Ikawa T, Shigeta Y, Ogawa T. Wear behavior of materials for fixed dental prostheses. Journal of Prosthodontic Research. 2026. doi:10.2186/jpr.jpr_d_25_00037

BibTeX
@article{Kojima2026,
  author = {Kojima, Kantaro and Kihara, Takuya and Ikawa, Tomoko and Shigeta, Yuko and Ogawa, Takumi},
  title = {Wear behavior of materials for fixed dental prostheses},
  journal = {Journal of Prosthodontic Research},
  year = {2026},
  doi = {10.2186/jpr.jpr_d_25_00037}
}