EUVIMEDEUVIMED entdecken
Crossref

Exploring the bio-mechanical behavior of PEEK and CFR-PEEK materials for dental implant applications using finite element analysis

Kandula Uday Kumar Reddy, Aqshat Seth, Amol Vuppuluri, Piyush Chandra Verma, Suresh Kumar Reddy Narala, Polavarapu Jayakrishna Babu, Prabakaran Saravanan

Journal of Prosthodontic Research · 2024

DOI: 10.2186/jpr.jpr_d_23_00296 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontic Research, 2024. Verfasst von Kandula Uday Kumar Reddy und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Birla Institute of Technology and Science (BITS), Pilani - Hyderabad Campus, Hyderabad, India. Hauptthemen laut MEDLINE: Finite Element Analysis, Polyethylene Glycols, Ketones, Dental Implants. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study explored the bio-mechanical properties of polyether ether ketone (PEEK) and carbon fiber reinforced-PEEK (CFR-PEEK) as potential alternatives to traditional dental implant materials, such as titanium (Ti) and zirconia (ZrO2). Conventional implant materials often exhibit stress shielding leading to peri-implant bone loss and implant failure. STUDY SELECTION: Finite element analysis using a three-dimensional computer-aided-design (3D CAD) model of the jawbone with various implant materials (titanium, zirconia, PEEK, and CFR-PEEK) incorporated was implemented to assess the effectiveness of PEEK and CFR-PEEK. Two loading conditions (50 and 100 N) were applied in centric (case-1) and eccentric (case-2) to mimic the oral loading conditions. RESULTS: Titanium and zirconia implants were found to exhibit higher levels of stress shielding and therefore pose greater risks of bone loss and implant failure. Conversely, CFR-PEEK implants demonstrated more-uniform stress distributions that reduce the likelihood of stress shielding compared to their conventional counterparts; consequently, CFR-PEEK implants are particularly suitable for load-bearing applications. Furthermore, maximum strain values on PEEK-implanted cortical bone reached a state of adaptation, referred to as the "lazy zone" in which bone growth and bone loss rates are equal, indicating PEEK's potential for a long-term implant utilization. CONCLUSIONS: PEEK and CFR-PEEK implants are promising alternatives to conventional dental implants because they provide stress shielding and promote bone health. Improved stress distribution enhances long-term success and durability while mitigating complications, and highlights their applicability to dental implant procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisPolyethylene GlycolsKetonesDental ImplantsCarbon FiberDental MaterialsCarbonBiocompatible MaterialsBenzophenonesPolymersStress, MechanicalComputer-Aided DesignMaterials TestingZirconiumDental Stress AnalysisTitaniumHumans

Stichwörter der Autor:innen

Bio-mechanicalDental implantsFinite element analysisPEEK polymerStress shielding

Substanzen

Polyethylene GlycolsKetonesDental ImplantsBenzophenonesPolymersCarbon Fiberpolyetheretherketonezirconium oxideZirconiumDental Materials

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Birla Institute of Technology and Science (BITS), Pilani - Hyderabad Campus, Hyderabad, India.
  • Department of Prosthodontics and crown and bridge, Army College of Dental Sciences (ACDS), Secunderabad, India.

Zitieren

APA

Reddy, K. U. K., Seth, A., Vuppuluri, A., Verma, P. C., Narala, S. K. R., Babu, P. J., & Saravanan, P. (2024). Exploring the bio-mechanical behavior of PEEK and CFR-PEEK materials for dental implant applications using finite element analysis. Journal of Prosthodontic Research. https://doi.org/10.2186/jpr.jpr_d_23_00296

Vancouver

Reddy KUK, Seth A, Vuppuluri A, Verma PC, Narala SKR, Babu PJ, et al. Exploring the bio-mechanical behavior of PEEK and CFR-PEEK materials for dental implant applications using finite element analysis. Journal of Prosthodontic Research. 2024. doi:10.2186/jpr.jpr_d_23_00296

BibTeX
@article{Reddy2024,
  author = {Reddy, Kandula Uday Kumar and Seth, Aqshat and Vuppuluri, Amol and Verma, Piyush Chandra and Narala, Suresh Kumar Reddy and Babu, Polavarapu Jayakrishna and Saravanan, Prabakaran},
  title = {Exploring the bio-mechanical behavior of PEEK and CFR-PEEK materials for dental implant applications using finite element analysis},
  journal = {Journal of Prosthodontic Research},
  year = {2024},
  doi = {10.2186/jpr.jpr_d_23_00296}
}
Kostenlos starten →