EUVIMEDEUVIMED entdecken
Crossref

Effects of implant abutment CAD/CAM design parameters on subgingival remnant cement

Fanghui Ji, Ji Hong Min, Oh Hwiseong, Ki Sun Lee, Jeongyol Lee, Jae Jun Ryu, Ji Suk Shim

Journal of Prosthodontic Research · 2026

DOI: 10.2186/jpr.jpr_d_24_00304 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontic Research, 2026. Verfasst von Fanghui Ji und 6 weiteren Autor:innen. Beteiligte Einrichtung: Dentistry, Department of Medicine, Korea University Graduate School, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Computer-Aided Design, Dental Implant-Abutment Design, Dental Cements, Dental Abutments. Die Arbeit nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To investigate the remnant cement in the subgingival regions (RCS) of abutments fabricated with different CAD/CAM parameters, including margin curvature radius, convergence angle, top fillet radius, and subgingival abutment shape. METHODS: Twelve experimental groups were fabricated to test the following parameters: abutment margin curvature radii of 0.8 mm, 1.2 mm, and 1.6 mm; convergence angles of 4°, 8°, and 12°; top fillet radii of 0.6 mm, 1.0 mm, and 1.4 mm; and subgingival abutment shapes of straight, S-curve, and concave. A constant amount of cement was injected into each crown. Vertical and continuous loads were applied to each specimen using a universal machine. RCS values were measured using a 3D intraoral scanner and an analytical balance. Statistical analysis was performed using one-way analysis of variance followed by post hoc Tukey test (α = .05). RESULTS: Regarding margin curvature radius, RCS values were significantly higher in the order of 1.6 mm, 1.2 mm, and 0.8 mm (P 8° > 4°(P 0.05). CONCLUSIONS: Within the limitations of this study, a smaller margin curvature radius, smaller convergence angle, and straight subgingival shape were associated with reduced RCS length, surface area, and weight.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignDental Implant-Abutment DesignDental CementsDental AbutmentsCrownsHumansDental Stress AnalysisGingiva

Stichwörter der Autor:innen

CAD/CAMCement-retainedDental implantImplant abutmentRemnant cement

Substanzen

Dental Cements

Autor:innen und Institutionen

  • Dentistry, Department of Medicine, Korea University Graduate School, Seoul, Republic of Korea.
  • Department of Dentistry, Korea University Ansan Hospital, Seoul, Republic of Korea.
  • Department of Dentistry, Korea University Guro Hospital, Seoul, Republic of Korea.
  • Department of Dentistry, Korea University Anam Hospital, Seoul, Republic of Korea.

Zitieren

APA

Ji, F., Min, J. H., Hwiseong, O., Lee, K. S., Lee, J., Ryu, J. J., & Shim, J. S. (2026). Effects of implant abutment CAD/CAM design parameters on subgingival remnant cement. Journal of Prosthodontic Research. https://doi.org/10.2186/jpr.jpr_d_24_00304

Vancouver

Ji F, Min JH, Hwiseong O, Lee KS, Lee J, Ryu JJ, et al. Effects of implant abutment CAD/CAM design parameters on subgingival remnant cement. Journal of Prosthodontic Research. 2026. doi:10.2186/jpr.jpr_d_24_00304

BibTeX
@article{Ji2026,
  author = {Ji, Fanghui and Min, Ji Hong and Hwiseong, Oh and Lee, Ki Sun and Lee, Jeongyol and Ryu, Jae Jun and Shim, Ji Suk},
  title = {Effects of implant abutment CAD/CAM design parameters on subgingival remnant cement},
  journal = {Journal of Prosthodontic Research},
  year = {2026},
  doi = {10.2186/jpr.jpr_d_24_00304}
}
Kostenlos starten →