EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Effect of internal connection type and screw channel angle on the screw stability of anterior implant‐supported zirconia crowns

Gülce Çakmak, Mehmet Esad Güven, Mustafa Borga Donmez iD, Çiğdem Kahveci, Martin Schimmel iD, Samir Abou-Ayash, Burak Yilmaz

Clinical Oral Implants Research · 2023

DOI: 10.1111/clr.14165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2023. Verfasst von Gülce Çakmak und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland. Hauptthemen laut MEDLINE: Dental Cements, Dental Implants. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Buser Implant Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To investigate the effect of implant–abutment connection and screw channel angle on screw stability by comparing a newly introduced and an established connection, before and after cyclic loading. Materials and Methods Implants ( N = 44) with Torcfit (TF) or Crossfit (CF) connection were divided to be restored with a straight (CFS and TFS) or an angled screw access channel (CFA and TFA) titanium‐base abutment ( n = 11). CFA and TFA received screw‐retained crowns, whereas CFS and TFS received hybrid zirconia abutments and cement‐retained crowns. The initial torque value (ITV) of each complex (ITV I ) and removal torque value (RTV) after 24 h (RTV I ) were measured. Screws were replaced with new ones, ITVs were recorded again (ITV F ), and crowns were cyclically loaded (2.4 million cycles, 98 N) to measure RTVs again (RTV F ). Percentage torque loss was calculated. Data were analyzed ( α = 0.05).

Results

ITVs were similar among groups ( p ≥ .089). CF led to higher RTVs ( p ≤ .002), while CFS had higher RTV I than CFA ( p = .023). After 24 h, CFS had lower percentage torque loss than TF, while CFA had lower percentage torque loss than TFA ( p ≤ .011). After cyclic loading, CF led to lower percentage torque ( p < .001).

Conclusion

The implant–abutment connection affected the removal torque values. However, no screw loosening occurred during cyclic loading, which indicated a stable connection for all groups. Screw access channel angle did not affect screw stability after cyclic loading.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental CementsDental ImplantsDental Stress AnalysisCrownsBone ScrewsTorqueTitaniumDental AbutmentsDental Implant-Abutment DesignMaterials TestingZirconium

Stichwörter der Autor:innen

angled screw channelimplant-abutment connectionscrew stabilitytorque loss

Substanzen

Dental CementsTitaniumDental Implantszirconium oxideZirconium

Autor:innen und Institutionen

  • Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
  • Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey.
  • Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey.
  • Ordu Oral and Dental Health Center, Ordu, Turkey.
  • Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland.

ORCID-Profile: Mustafa Borga Donmez, Martin Schimmel

Förderung

  • Buser Implant Foundation

Zitieren

APA

Çakmak, G., Güven, M. E., Donmez, M. B., Kahveci, Ç., Schimmel, M., Abou-Ayash, S., & Yilmaz, B. (2023). Effect of internal connection type and screw channel angle on the screw stability of anterior implant‐supported zirconia crowns. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14165

Vancouver

Çakmak G, Güven ME, Donmez MB, Kahveci Ç, Schimmel M, Abou-Ayash S, et al. Effect of internal connection type and screw channel angle on the screw stability of anterior implant‐supported zirconia crowns. Clinical Oral Implants Research. 2023. doi:10.1111/clr.14165

BibTeX
@article{akmak2023,
  author = {Çakmak, Gülce and Güven, Mehmet Esad and Donmez, Mustafa Borga and Kahveci, Çiğdem and Schimmel, Martin and Abou-Ayash, Samir and Yilmaz, Burak},
  title = {Effect of internal connection type and screw channel angle on the screw stability of anterior implant‐supported zirconia crowns},
  journal = {Clinical Oral Implants Research},
  year = {2023},
  doi = {10.1111/clr.14165}
}
Kostenlos starten →