The residual monomer content and mechanical properties of CAD\CAM resins used in the fabrication of complete dentures as compared to heat cured resins

Al-Dharrab Ayman

Electronic Physician · 2017-07-25 · 9 (7) · 4766-4772

DOI: 10.19082/4766 ↗

At a glance

Journal article in Electronic Physician, published online on 2017-07-25. Written by Al-Dharrab Ayman. Institution: Ph.D., Associate Professor & Consultant in Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jedd…. Cited 115 times so far (Crossref). The full text is freely available in PubMed Central.

AchoimreSubjectsSonraí leabharliostaCiteRelated studies

Abstract (original language)

BACKGROUND: The utilization of computer-assisted designing and computer-assisted milling CAD\CAM resins in the fabrication of removable prostheses is a modern-day concept that offers many advantages over the use of the traditional polymethylmethacrylate (PMMA). AIM: This study instigated some of the mechanical properties of CAD\CAM denture base resin including the amount of residual monomer. METHODS: This study was conducted at the Faculty of Dentistry, King Abdulaziz University from October 2016 to February 2017. A total of seventy rectangular specimens were fabricated (group A: 35 heat-cured PMMA and group B: 35 CAD/CAM pre-polymerized acrylic resin blocks). The flexural strength and surface hardness were tested while the residual monomer content at baseline, two-day and seven-day intervals was estimated using gas chromatography (GC). Means and standard deviations were determined for each group as well as independent-samples t-test and ANOVA with repeated measures for comparison between the groups and subgroups of varying time intervals. RESULTS: Heat cured PMMA (A), displayed higher flexural strength and low value flexural modulus compared to CAD/CAM acrylic resin denture base material (B). Student t-test indicated highly significant differences (p

Subjects

Author keywords

Acrylic resinDenturesFlexural strengthResidual monomerSurface hardness

Authors and institutions

  • Ph.D., Associate Professor & Consultant in Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.

Cite

APA

Ayman, A. D. (2017). The residual monomer content and mechanical properties of CAD\CAM resins used in the fabrication of complete dentures as compared to heat cured resins. Electronic Physician, 9(7), 4766-4772. https://doi.org/10.19082/4766

Vancouver

Ayman AD. The residual monomer content and mechanical properties of CAD\CAM resins used in the fabrication of complete dentures as compared to heat cured resins. Electronic Physician. 2017;9(7):4766-4772. doi:10.19082/4766

BibTeX
@article{Ayman2017,
  author = {Ayman, Al-Dharrab},
  title = {The residual monomer content and mechanical properties of CAD\CAM resins used in the fabrication of complete dentures as compared to heat cured resins},
  journal = {Electronic Physician},
  year = {2017},
  volume = {9},
  number = {7},
  pages = {4766--4772},
  doi = {10.19082/4766}
}
Start for free →