Trueness and precision of artificial teeth in CAD-CAM milled complete dentures from custom disks with a milled recess
The Journal of Prosthetic Dentistry · 2024-11 · 132 (5) · 1014-1019
DOI: 10.1016/j.prosdent.2022.08.037 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-11. Verfasst von Yumika Soeda und 5 weiteren Autor:innen. Beteiligte Einrichtung: Dental Resident, Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental Univer…. Hauptthemen laut MEDLINE: Computer-Aided Design, Tooth, Artificial, Denture Design, Denture, Complete. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Studies on the movement of artificial teeth during the manufacturing of computer-aided design and computer-aided manufacturing (CAD-CAM) complete dentures using the custom disk method with milled recesses and on whether the movement is within a clinically acceptable range are lacking. PURPOSE: The purpose of this in vitro study was to assess the trueness and precision of the artificial teeth on custom disks the recesses of which were manufactured using a milling machine and to compare the results with the recesses manufactured using a 3-dimensional (3D) printer. MATERIAL AND METHODS: Four types of artificial teeth (maxillary left central incisors [Max-L1], mandibular left central incisors [Man-L1], maxillary left first premolars [Max-L4], and maxillary left first molars [Max-L6]) were prepared. Milling data were created, and 3 of each type of tooth were attached to each disk made up of 3 concentric circles (large, medium, and small). Five each of the 3D printed custom disks and custom disks with milled recesses were milled based on the milling data. Standard tessellation language data were obtained through cone beam computed tomography and superimposed by using a CAD software program. Mean absolute error (MAE) values were calculated to assess trueness and precision; MAE values of artificial teeth in custom disks with milled recesses and 3D printed custom disks were statistically compared by using the 2-way analysis of variance test with 2 factors, 2 types of custom disks and 4 types of artificial teeth, and the Tukey post hoc comparison (α=.05). RESULTS: Regarding position trueness, the MAE value of Man-L1 on the milling custom disk was significantly lower than that of the 3D printed custom disk (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Dental Resident, Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Bunkyo, Tokyo, Japan.
- Junior Associate Professor, Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Bunkyo, Tokyo, Japan. Electronic address: y.ko…
- Professor, Department of Digital Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Bunkyo, Tokyo, Japan.
- Adjunct Lecturer, Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Bunkyo, Tokyo, Japan.
- Associate Professor, Department of Digital Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Bunkyo, Tokyo, Japan.
- Professor, Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Bunkyo, Tokyo, Japan.
Zitieren
APA
Soeda, Y., Komagamine, Y., Kanazawa, M., Hada, T., Iwaki, M., & Minakuchi, S. (2024). Trueness and precision of artificial teeth in CAD-CAM milled complete dentures from custom disks with a milled recess. The Journal of Prosthetic Dentistry, 132(5), 1014-1019. https://doi.org/10.1016/j.prosdent.2022.08.037
Vancouver
Soeda Y, Komagamine Y, Kanazawa M, Hada T, Iwaki M, Minakuchi S. Trueness and precision of artificial teeth in CAD-CAM milled complete dentures from custom disks with a milled recess. The Journal of Prosthetic Dentistry. 2024;132(5):1014-1019. doi:10.1016/j.prosdent.2022.08.037
BibTeX
@article{Soeda2024,
author = {Soeda, Yumika and Komagamine, Yuriko and Kanazawa, Manabu and Hada, Tamaki and Iwaki, Maiko and Minakuchi, Shunsuke},
title = {Trueness and precision of artificial teeth in CAD-CAM milled complete dentures from custom disks with a milled recess},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
volume = {132},
number = {5},
pages = {1014--1019},
doi = {10.1016/j.prosdent.2022.08.037}
}
EUVIMED