Comparative Analysis of the Effects of Different Disinfection Methods on the Mechanical Properties of Valplast and Acrylic Resin Denture Base Materials
Erbil Dental Journal · 30.06.2026 · 9 (1) · 96-103
DOI: 10.15218/edj.2026.11 ↗Kurz gefasst
Fachartikel in der Zeitschrift Erbil Dental Journal, online erschienen am 30.06.2026. Verfasst von Ribaz Tahsin Hayas Kakai.
Abstract (Originalsprache)
Background and objective: Dental prostheses should be disinfected effectively without damaging the denture base.
Aim
This in vitro study evaluates the effect of three commonly used chemical disinfectants, 4% chlorhexidine, 2% glutaraldehyde, and 5.25% sodium hypochlorite, on the mechanical properties of two widely used denture base materials: Heat-cured acrylic resin and Valplast.
Methods
A total of 160 rectangular specimens were fabricated and equally divided into two main material groups (80 specimens of Heat-cured acrylic resin and 80 specimens of Valplast). Each group was further subdivided into four subgroups (n=20) according to the disinfectant applied, including a control group with distilled water. Disinfection protocols involved immersing each specimen in distilled water for 3 minutes, followed by a 10-minute exposure to the designated disinfectant, and concluding with a 3-minute washing in distilled water. Flexural strength and flexural modulus were assessed using a universal testing machine based on the three-point bending test according to ISO 178:2019 standards.
Results
Statistical analysis was conducted using one-way ANOVA, Dunnett’s post hoc, and an independent t-test at a significance level of P ≤ 0.05. The flexural strength test indicated that, for both main groups, the control group exhibited the highest mean values, while specimens immersed in 5.25% sodium hypochlorite recorded the lowest mean values and showed no significant differences between Heat-cured acrylic resin and Valplast materials under corresponding treatment conditions.
Conclusion
These findings suggest that disinfection protocols do not impact the mechanical properties of denture base materials, and Valplast consistently exhibited lower values in both parameters compared to Heat-cured acrylic resin. Keywords: Heat-cured acrylic resin, Valplast, Flexural strength, Flexural modulus, chemical disinfectant
Zitieren
APA
Kakai, R. T. H. (2026). Comparative Analysis of the Effects of Different Disinfection Methods on the Mechanical Properties of Valplast and Acrylic Resin Denture Base Materials. Erbil Dental Journal, 9(1), 96-103. https://doi.org/10.15218/edj.2026.11
Vancouver
Kakai RTH. Comparative Analysis of the Effects of Different Disinfection Methods on the Mechanical Properties of Valplast and Acrylic Resin Denture Base Materials. Erbil Dental Journal. 2026;9(1):96-103. doi:10.15218/edj.2026.11
BibTeX
@article{Kakai2026,
author = {Kakai, Ribaz Tahsin Hayas},
title = {Comparative Analysis of the Effects of Different Disinfection Methods on the Mechanical Properties of Valplast and Acrylic Resin Denture Base Materials},
journal = {Erbil Dental Journal},
year = {2026},
volume = {9},
number = {1},
pages = {96--103},
doi = {10.15218/edj.2026.11}
}
EUVIMED