EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

GaneStat—A comprehensive design and modular analysis of portable, low-cost, and high-accuracy potentiostat

Isa Anshori iD, Infall Syafalni iD, Christian Reivan, Iqbal Fawwaz Ramadhan, Theodore Maximillan Jonathan, Rizky Indah Sari, Uperianti, Trio Adiono, Chih-Yu Chang, Akhmadi Surawijaya iD

PLOS One · 21.11.2025 · 20 (11) · e0335917

DOI: 10.1371/journal.pone.0335917 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 21.11.2025. Verfasst von Isa Anshori und 9 weiteren Autor:innen. Beteiligte Einrichtung: Lab on Chip Laboratory, Biomedical Engineering Department, School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Ind…. Hauptthemen laut MEDLINE: Electrochemical Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institut Teknologi Bandung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemical research has been developing with the advancement of laboratory equipment and sophisticated technologies. One of which is the portable potentiostat, which has been utilized to analyze various samples and help characterize their electrochemical properties. In this paper, we propose a comprehensive design and modular analysis of our proposed potentiostat called GaneStat. The proposed potentiostat has a low cost, portable, and high accuracy with battery-powered and electrical overstress circuit protection. The proposed analog front end of the potentiostat consists of several modules such as unipolar-to-bipolar converter (UBC), buffer, current-to-voltage converter (CVC), bipolar-to-unipolar converter (BUC), two-stage sallen key low-pass filter, and ADC input protection unit (AIPC). A maximum wide dynamic range of 98.95 dB provides flexibility in terms of current measurement. The potentiostat is also equipped with a dedicated power management circuit and an overstress protection circuit. Multi mode measurements are provided in our system for Cyclic voltammetry (CV), differential pulse voltammetry (DPV), Linear Sweep Voltammetry (LSV), and Chronoamperometry (CA) experiments with preliminary test on redox probe solution to validate the performance of the device. The final design occupies relatively small space of 6.95cm × 6.85 cm × 3.26 cm with 83.1 gr of weight, including the battery and the case. The potentiostat operates with sweep voltage within ±2.5 V with a 1.2 mV resolution, and it can measure current from 10 nA to 10 mA with 0.53 nA and 0.3 μ A resolutions, respectively. The potentiostat costs only $98.55 for the prototyping. This work is useful for laboratory applications in chemical, pharmacy and medical industries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrochemical TechniquesEquipment Design

Autor:innen und Institutionen

  • Lab on Chip Laboratory, Biomedical Engineering Department, School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia.
  • Research Center for Nanoscience and Nanotechnology, Institut Teknologi Bandung, Bandung, Indonesia.
  • ITB Center for Health snd Sports Technology (PTKK-ITB), Institut Teknologi Bandung, Bandung, Indonesia.
  • School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia.
  • University Center of Excellence on Microelectronics, Institut Teknologi Bandung, Bandung, Indonesia.
  • Department of Nanotechnology, Graduate School, Institut Teknologi Bandung, Bandung, Indonesia.

ORCID-Profile: Isa Anshori, Infall Syafalni, Akhmadi Surawijaya

Förderung

  • Institut Teknologi Bandung

Zitieren

APA

Anshori, I., Syafalni, I., Reivan, C., Ramadhan, I. F., Jonathan, T. M., Sari, R. I., Uperianti, Adiono, T., Chang, C. Y., & Surawijaya, A. (2025). GaneStat—A comprehensive design and modular analysis of portable, low-cost, and high-accuracy potentiostat. PLOS One, 20(11), e0335917. https://doi.org/10.1371/journal.pone.0335917

Vancouver

Anshori I, Syafalni I, Reivan C, Ramadhan IF, Jonathan TM, Sari RI, et al. GaneStat—A comprehensive design and modular analysis of portable, low-cost, and high-accuracy potentiostat. PLOS One. 2025;20(11):e0335917. doi:10.1371/journal.pone.0335917

BibTeX
@article{Anshori2025,
  author = {Anshori, Isa and Syafalni, Infall and Reivan, Christian and Ramadhan, Iqbal Fawwaz and Jonathan, Theodore Maximillan and Sari, Rizky Indah and Uperianti and Adiono, Trio and Chang, Chih-Yu and Surawijaya, Akhmadi},
  title = {GaneStat—A comprehensive design and modular analysis of portable, low-cost, and high-accuracy potentiostat},
  journal = {PLOS One},
  year = {2025},
  volume = {20},
  number = {11},
  pages = {e0335917},
  doi = {10.1371/journal.pone.0335917}
}
Kostenlos starten →