Paper-based graphene bioelectrode enabling third-generation fructose dehydrogenase sensing of inulin
Biosensors and Bioelectronics · 2026
DOI: 10.1016/j.bios.2025.118347 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von D Paolini und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" Via R. Balzarini 1, 64…. Hauptthemen laut MEDLINE: Biosensing Techniques, Graphite, Inulin, Carbohydrate Dehydrogenases. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, Ministero dell'Università e della Ricerca.
Abstract (Originalsprache)
Here, the first paper-based direct electron-transfer enzymatic biosensor is presented. This is the first biosensor designed to enable simple detection of inulin in biological fluids, serving as an exogenous marker for estimating glomerular filtration rate (GFR). The biosensor relies on a laser-induced graphene (LIG) paper-based sensor integrating Fructose Dehydrogenase (FDH). This enzyme was incorporated into paper for the first time in this work and demonstrated direct electron transfer (DET) capability. Various cellulosic substrates were evaluated as biosensor supports, and a tree-free bamboo-derived paper (FB) was selected for its ability to accommodate both LIG as the transducer film and FDH as the bioreceptor. The FB-LIG, which yielded the highest bioelectrocatalytic response, was employed to determine inulin in human urine and serum in the context of GFR studies. The FB-LIG biosensor was selective, and via matrix-matched calibration was used to determine inulin in samples, obtaining useful dose-response linearity (urine: 1.6-22.7 mg L-1; serum: 4.6-11.4 mg L-1) and the needed sensitivity (LOD: urine = 0.3 mg L-1, serum = 1.0 mg L-1), together with high reproducibility (RSD ≤2.0 %, n = 3). The complete inulin analysis takes less than 10 min and includes a rapid hydrolysis step followed by direct biosensor measurement. The FB-LIG biosensor reliability was demonstrated by measuring inulin in real urine and serum samples at clinically relevant levels, achieving satisfactory recoveries (90-111 %; RSD ≤7.9 %, n = 3). Here, for the first time, a sustainable substrate enabled the development of a paper-based third-generation biosensor, demonstrating the potential of LIG on paper for bioelectrocatalysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" Via R. Balzarini 1, 64100, Teramo, Italy.
- Department of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" Via R. Balzarini 1, 64100, Teramo, Italy. Electronic address: fdellapelle@unite.it.
- Department of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" Via R. Balzarini 1, 64100, Teramo, Italy; University School for Advanced Studies IUSS Pavia,…
- Department of Chemistry, University of Bari Aldo Moro, Via E. Orabona 4, 70125, Bari, Italy; Centre for Colloid and Surface Science - University of Bari Aldo Moro, Via Edoardo Orabona 4, 70125, Bari, Italy.
- Division of Applied Life Sciences, Graduate School of Agriculture, Kyoto University, Kitashirakawa Oiwake-cho, Sakyo-ku, Kyoto, 606-8502, Japan.
- Department of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" Via R. Balzarini 1, 64100, Teramo, Italy. Electronic address: dcompagnone@unite.it.
Förderung
- European Commission
- Ministero dell'Università e della Ricerca
Zitieren
APA
Paolini, D., Silveri, F., Della Pelle, F., Di Cristoforo, I. V., Scroccarello, A., Bollella, P., Torsi, L., Notarstefano, V., Fukawa, E., Suzuki, Y., Sowa, K., & Compagnone, D. (2026). Paper-based graphene bioelectrode enabling third-generation fructose dehydrogenase sensing of inulin. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118347
Vancouver
Paolini D, Silveri F, Della Pelle F, Di Cristoforo IV, Scroccarello A, Bollella P, et al. Paper-based graphene bioelectrode enabling third-generation fructose dehydrogenase sensing of inulin. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118347
BibTeX
@article{Paolini2026,
author = {Paolini, D and Silveri, F and Della Pelle, F and Di Cristoforo, I V and Scroccarello, A and Bollella, P and Torsi, Luisa and Notarstefano, V and Fukawa, E and Suzuki, Y and Sowa, K and Compagnone, D},
title = {Paper-based graphene bioelectrode enabling third-generation fructose dehydrogenase sensing of inulin},
journal = {Biosensors and Bioelectronics},
year = {2026},
doi = {10.1016/j.bios.2025.118347}
}
EUVIMED