Bilisense: An affordable sensor for on-site diagnosis of jaundice and prevention of kernicterus
Biosensors and Bioelectronics · 2025
DOI: 10.1016/j.bios.2025.117386 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Victor Ong und 12 weiteren Autor:innen. Beteiligte Einrichtung: Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, STE 140, Los Angeles, 90089, CA, USA. Hauptthemen laut MEDLINE: Biosensing Techniques, Bilirubin, Kernicterus, Jaundice. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 77 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Bilirubin (BR) in blood serum is elevated during jaundice (a common complication among newborns). Accessible and frequent monitoring of BR is necessary for timely diagnosis and intervention. This work developed a low-cost electrochemical sensor for point-of-care and at-home measurement of BR. The sensor measures BR based on its oxidation at a laser-induced graphene electrode. A microfluidic channel for sample wicking is embedded on the electrodes to bifurcate the blood sample into two zones to allow measurement of different BR forms (conjugated and unconjugated). One zone remains bare, while the second zone is impregnated with caffeine sodium benzoate, which acts as an accelerant to release albumin-bound BR and makes it accessible for electrochemical oxidation. The sensors demonstrate linear response in the concentration range of 100 to 500 µmolL-1 total bilirubin (4:1 ratio of unconjugated to conjugated bilirubin) in undiluted blood serum. Physiologically relevant BR levels range from 170 µmolL-1 (healthy concentrations) to 460 µmolL-1 (elevated, unhealthy concentration). Recovery values at 150 and 250 µmolL-1 are 119 % and 104 %, which fall within the 20 % error required by the United States Food and Drug Administration. This device represents the first point-of-care bilirubin-sensor capable of distinguishing between different forms of bilirubin.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, STE 140, Los Angeles, 90089, CA, USA.
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, STE 140, Los Angeles, 90089, CA, USA; Department of Chemistry, University of Southern California, 3620 McClintock…
Förderung
- NIGMS NIH HHS
- National Institutes of Health
Zitieren
APA
Ong, V., Mohamed, M. A., Ma, H., Al-Shami, A., Khazaee Nejad, S., Amirghasemi, F., Tabassum, A., Lee, M. J., Rohleder, A., Zhu, C., Tam, C., Nowlen, P., & Mousavi, M. P. S. (2025). Bilisense: An affordable sensor for on-site diagnosis of jaundice and prevention of kernicterus. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117386
Vancouver
Ong V, Mohamed MA, Ma H, Al-Shami A, Khazaee Nejad S, Amirghasemi F, et al. Bilisense: An affordable sensor for on-site diagnosis of jaundice and prevention of kernicterus. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117386
BibTeX
@article{Ong2025,
author = {Ong, Victor and Mohamed, Mona A and Ma, Haozheng and Al-Shami, Abdulrahman and Khazaee Nejad, Sina and Amirghasemi, Farbod and Tabassum, Asna and Lee, Michael Jayden and Rohleder, Alexander and Zhu, Cathy and Tam, Chur and Nowlen, Patrick and Mousavi, Maral P S},
title = {Bilisense: An affordable sensor for on-site diagnosis of jaundice and prevention of kernicterus},
journal = {Biosensors and Bioelectronics},
year = {2025},
doi = {10.1016/j.bios.2025.117386}
}
EUVIMED