EUVIMEDEUVIMED entdecken
Crossref

Single-channel electrochemical biosensor for simultaneous monitoring of glucose and uric acid

Changyun Quan, Liping Wen, Minghui Yang, Binjie Xu

Biosensors and Bioelectronics · 2026-02 · 294 · 118255

DOI: 10.1016/j.bios.2025.118255 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-02. Verfasst von Changyun Quan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University,…. Hauptthemen laut MEDLINE: Uric Acid, Biosensing Techniques, Blood Glucose, Electrochemical Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Hunan Provincial Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Given the metabolic interplay between glucose and uric acid, individuals should proactively monitor and be alert of elevated levels of both substances. For the first time, this paper describes a novel design of electrochemical biosensor based on screen-printed electrode of a single channel but capable of simultaneously measuring blood glucose and uric acid concentrations. Experimental results demonstrated that this single-channel biosensor exhibits good performance towards glucose and uric acid, such as broad linear range, good reproducibility, good stability, and strong resistance against interference. For spiked recovery experiments on human venous blood samples, the glucose recovery rate ranged from 95.9 % to 103.2 %, while the uric acid recovery rate ranged from 99.7 % to 104.9 %. And the relative standard deviation for both parameters was less than 5 %, indicating that this biosensor holds promising prospects for commercial application. This is truly the first time that enable simultaneous detection of glucose and uric acid concentrations using just one drop of blood and a single test strip. It reduces the number of blood draws required, lowers analysis costs, and significantly improves screening efficiency for individuals with diabetes and hyperuricemia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Uric AcidBiosensing TechniquesBlood GlucoseElectrochemical TechniquesHumansEquipment DesignReproducibility of ResultsHyperuricemiaLimit of DetectionElectrodes

Stichwörter der Autor:innen

GlucoseScreen-printed electrodeSingle-channel electrochemical biosensorUric acid

Substanzen

Uric AcidBlood Glucose

Autor:innen und Institutionen

  • Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China; Cofoe Medical Technology Co., Ltd., No. 87,…
  • Cofoe Medical Technology Co., Ltd., No. 87, Section 1, Huanbao East Road, Changsha, 410000, China.
  • Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China; National Engineering Research Center of Pers…
  • Cofoe Medical Technology Co., Ltd., No. 87, Section 1, Huanbao East Road, Changsha, 410000, China. Electronic address: binjie.xu@outlook.com.

Förderung

  • National Natural Science Foundation of China
  • Hunan Provincial Natural Science Foundation

Zitieren

APA

Quan, C., Wen, L., Yang, M., & Xu, B. (2026). Single-channel electrochemical biosensor for simultaneous monitoring of glucose and uric acid. Biosensors and Bioelectronics, 294, 118255. https://doi.org/10.1016/j.bios.2025.118255

Vancouver

Quan C, Wen L, Yang M, Xu B. Single-channel electrochemical biosensor for simultaneous monitoring of glucose and uric acid. Biosensors and Bioelectronics. 2026;294:118255. doi:10.1016/j.bios.2025.118255

BibTeX
@article{Quan2026,
  author = {Quan, Changyun and Wen, Liping and Yang, Minghui and Xu, Binjie},
  title = {Single-channel electrochemical biosensor for simultaneous monitoring of glucose and uric acid},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {294},
  pages = {118255},
  doi = {10.1016/j.bios.2025.118255}
}
Kostenlos starten →