EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Versatile conductometric biosensors for rapid and selective detection of inflammatory and cardiac biomarkers in saliva

Preethi Chidambaram, Saleha Sarowat Sakeeba, Nithya Eswaramoorthy, Fateme Akhlaghi Bagherjeri, Hassan Monhemi, Madhu Bhaskaran, Ganganath S Perera, Sharath Sriram

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2024.116516 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Preethi Chidambaram und 7 weiteren Autor:innen. Beteiligte Einrichtung: Functional Materials and Microsystems Research Group and the Micro Nano Research Facility, RMIT University, Melbourne, Australia. Hauptthemen laut MEDLINE: Biosensing Techniques, Biomarkers, Saliva, Troponin I. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biosensors have become promising alternatives to the conventional methods in early identification of diseases. However, translation of biosensors from lab to commercial products have challenges such as complex sensor fabrications and complicated detection, and inadequate sensitivity and selectivity. Here, we introduce simple and low-cost fabricated conductometric sensors based on high resistivity silicon wafers (HR-Si) which can be adopted to functionalise with both natural and synthetic antibodies in detecting five biomarkers including interleukin-6, C reactive protein, cardiac troponin I, brain natriuretic peptide, and N terminal-probrain natriuretic peptide. All five biomarkers show selective and rapid (10 min sample incubation and

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesBiomarkersSalivaTroponin INatriuretic Peptide, BrainHumansC-Reactive ProteinLimit of DetectionInterleukin-6Equipment DesignSiliconPeptide FragmentsAntibodies, ImmobilizedInflammation

Stichwörter der Autor:innen

BNPCRPIL-6NT-proBNPcTnI

Substanzen

BiomarkersTroponin INatriuretic Peptide, BrainC-Reactive ProteinInterleukin-6pro-brain natriuretic peptide (1-76)SiliconPeptide FragmentsAntibodies, Immobilized

Autor:innen und Institutionen

  • Functional Materials and Microsystems Research Group and the Micro Nano Research Facility, RMIT University, Melbourne, Australia.
  • Department of Chemistry, Faculty of Science, University of Neyshabur, Iran.
  • Functional Materials and Microsystems Research Group and the Micro Nano Research Facility, RMIT University, Melbourne, Australia. Electronic address: ganganath.perera@rmit.edu.au.
  • Functional Materials and Microsystems Research Group and the Micro Nano Research Facility, RMIT University, Melbourne, Australia. Electronic address: sharath.sriram@rmit.edu.au.

Förderung

  • Australian Research Council

Zitieren

APA

Chidambaram, P., Sakeeba, S. S., Eswaramoorthy, N., Bagherjeri, F. A., Monhemi, H., Bhaskaran, M., Perera, G. S., & Sriram, S. (2024). Versatile conductometric biosensors for rapid and selective detection of inflammatory and cardiac biomarkers in saliva. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116516

Vancouver

Chidambaram P, Sakeeba SS, Eswaramoorthy N, Bagherjeri FA, Monhemi H, Bhaskaran M, et al. Versatile conductometric biosensors for rapid and selective detection of inflammatory and cardiac biomarkers in saliva. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116516

BibTeX
@article{Chidambaram2024,
  author = {Chidambaram, Preethi and Sakeeba, Saleha Sarowat and Eswaramoorthy, Nithya and Bagherjeri, Fateme Akhlaghi and Monhemi, Hassan and Bhaskaran, Madhu and Perera, Ganganath S and Sriram, Sharath},
  title = {Versatile conductometric biosensors for rapid and selective detection of inflammatory and cardiac biomarkers in saliva},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2024.116516}
}
Kostenlos starten →