Comparison of laryngeal tube evo with tracheal intubation during intra-arrest-ventilation using biphasic positive pressure ventilation - a prospective randomized controlled body donor study
Critical Care · 2026-03-28 · 30 (1)
DOI: 10.1186/s13054-026-05902-4 ↗At a glance
Randomisierte kontrollierte Studie in Critical Care, published online on 2026-03-28. Written by Gerrit Jansen and 13 co-authors. Institution: University Department of Anaesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Medicine, Ruhr University of Bochum, Johannes Wesling …. Major MEDLINE topics: Intubation, Intratracheal, Positive-Pressure Respiration. 25 references. The full text is freely available (open access, CC BY 4.0). Funded by: Ruhr-Universität Bochum.
Abstract (original language)
Background
This study evaluates the effects of the new supraglottic airway-device laryngeal tube evo (LT ® evo) versus that of tracheal intubation (TI) concerning the target parameters of ventilation therapy during mechanical chest compressions in intra-arrest-ventilation with biphasic-positive-airway-pressure-ventilation.
Methods
This prospective randomized crossover study involving Thiel-embalmed human body donors, compares TI with LT ® evo using biphasic-positive-airway-pressure-ventilation during mechanical cardiopulmonary resuscitation. Each body donor underwent ventilation with both airway-devices in randomized order. Ventilatory parameters were recorded at ventilator flow sensors. Primary endpoint was expiratory tidal volume (VT e ), secondary endpoints included expiratory tidal volume per kg ideal body weight (VT e /kgIBW); delta tidal volume (ideal-VT e ; ΔVT); leakage volume (V Leak ); peak (P Peak ), mean (P Mean ), plateau (P Plat ) pressures; and respiratory rates.
Results
Five body donors were included. Linear regression analyses with random intercepts revealed lower VT e (-295.7 ± 8 ml; 95%CI:-339.2 to -252.2); p < 0.0001), VT e /kgIBW (-5.0 ml/kg; 95%:-5.7 to -4.2; p < 0.0001), P Peak (-19.0mbar; 95%CI:-23.1 to -14.9; p < 0.0001) and P Mean (-2mbar; 95%CI:-3.2 to -0.8 ; p = 0.001) but higher ∆VT (296.0 ml; 95%CI:252.5 to 339.4; p < 0.0001) and V Leak (52.7%; 95%CI:41.6 to 63.7; p < 0.0001) for LT ® evo. While all tracheal-intubated body donors (100%) were successfully ventilated with biphasic-positive-airway-pressure-ventilation (VT e /kgIBW > 2 ml/kg), only one of five body donors (20%) could be ventilated via LT ® evo.
Conclusion
In this body donor model of biphasic-positive-airway-pressure-ventilation during mechanical cardiopulmonary resuscitation, TI provided higher VT e and lower leakage than LT ® evo did. LT ® evo ventilation frequently failed to achieve tidal volumes above the estimated dead space. These findings suggest that LT ® evo may be poorly suited for intra-arrest ventilation using biphasic-positive-airway-pressure-ventilation during mechanical cardiopulmonary resuscitation. When the LT ® evo is used in this setting, a synchronous 30:2 ventilation strategy may represent a safer alternative.
Trial registration
German Clinical Trials Register; unique identifier: DRKS00037836; registration date: September 09, 2025.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- University Department of Anaesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Medicine, Ruhr University of Bochum, Johannes Wesling Klinikum Minden, Hans- Nolte-Straße 1, 32429, Minden, Germany.
- Institute of Anatomy, Medical Faculty of Ruhr University Bochum, Ruhr University Bochum, Universitätsstraße 150, 44801, Bochum, Germany.
- Medical Faculty of Ruhr University Bochum, Ruhr University Bochum, Universitätsstraße 150, 44801, Bochum, Germany. Cornelius.Falk@edu.ruhr-uni-bochum.de.
- Dpt. of Anesthesiology, Critical Care, Emergency and Pain Medicine, German Armed Forces Hospital Ulm, 89081, Ulm, Germany.
- Medical Faculty, University of Heidelberg, Heidelberg, Germany.
- Medical School OWL, Biostatistics and Medical Biometry, Bielefeld University, Universitätsstraße 25, 33615, Bielefeld, Germany.
Funding
- Ruhr-Universität Bochum
Cite
APA
Jansen, G., Varghese, L. J. K., Brand-Saberi, B., Falk, C. C., Feth, M., Förster, E., Gelashvili, T., Genzwürker, H., Hoyer, A., Ihlenfeld, M., Pooth, J. S., Thomasseck, A., Trenkel, J., & Tiesmeier, J. (2026). Comparison of laryngeal tube evo with tracheal intubation during intra-arrest-ventilation using biphasic positive pressure ventilation - a prospective randomized controlled body donor study. Critical Care, 30(1). https://doi.org/10.1186/s13054-026-05902-4
Vancouver
Jansen G, Varghese LJK, Brand-Saberi B, Falk CC, Feth M, Förster E, et al. Comparison of laryngeal tube evo with tracheal intubation during intra-arrest-ventilation using biphasic positive pressure ventilation - a prospective randomized controlled body donor study. Critical Care. 2026;30(1). doi:10.1186/s13054-026-05902-4
BibTeX
@article{Jansen2026,
author = {Jansen, Gerrit and Varghese, Lydia Johnson Kolaparambil and Brand-Saberi, Beate and Falk, Cornelius Christopher and Feth, Maximilian and Förster, Eckart and Gelashvili, Tamar and Genzwürker, Harald and Hoyer, Annika and Ihlenfeld, Marcel and Pooth, Jan-Steffen and Thomasseck, Amy and Trenkel, Justin and Tiesmeier, Jens},
title = {Comparison of laryngeal tube evo with tracheal intubation during intra-arrest-ventilation using biphasic positive pressure ventilation - a prospective randomized controlled body donor study},
journal = {Critical Care},
year = {2026},
volume = {30},
number = {1},
doi = {10.1186/s13054-026-05902-4}
}
EUVIMED