Randomized Crossover Comparison of the Airway‐Exchange Broncholaryngoscope and Aintree Catheter
The Laryngoscope · 2026
DOI: 10.1002/lary.70006 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Laryngoscope, 2026. Verfasst von Roger W Boles und 5 weiteren Autor:innen. Beteiligte Einrichtung: Caruso Department of Otolaryngology - Head and Neck Surgery, Keck Medicine of the University of Southern California, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Bronchoscopy, Catheters, Intubation, Intratracheal. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
Objectives
The Airway‐Exchange Broncholaryngoscope (AEBLScope) combines a bronchoscope and airway‐exchange catheter (AEC) into a single device, enabling visual placement of AECs and increasing the efficiency and accuracy of airway‐exchange procedures (AEP). The purpose of this study was to compare the AEBLScope with the Aintree Intubation Catheter (Aintree) for AEPs in airway models.
Methods
Thirty‐eight Otolaryngologists, Anesthesiologists, and Critical Care providers performed AEPs on tracheostomy (trach) and endotracheal (ETT) airway models. Participants were randomized by which device and model were used first. AEPs were timed. Devices were rated using a 7‐point Likert scale on ease‐of‐use, effectiveness, and likelihood to use again. Finally, practitioners selected which device they preferred overall.
Results
Participants significantly preferred the AEBLScope to the Aintree (31 vs. 7, p < 0.001). Accounting for randomization, the AEBLScope was significantly faster for performing AEPs on ETTs (56.46 vs. 62.13 s, FDR ‐Adjusted p = 0.04). AEPs for trachs were performed faster with the AEBLScope compared with the Aintree (44.28 vs. 49.00 s, FDR ‐Adjusted p = 0.08), but this was not statistically significant. Participants rated the AEBLScope as significantly easier to use than the Aintree (5.11 vs. 4.66, p = 0.015). Additionally, the AEBLScope was rated as more effective (5.43 vs. 5.14, p = 0.067) and more likely to use again (5.32 vs. 5.00, p = 0.083), however these results were not statistically significant.
Conclusions
The AEBLScope was preferred for AEPs, was easier to use, and performed AEPs faster than Aintree. Further testing must assess the efficacy of the AEBLScope for AEPs in patients. Level of Evidence N/A.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Caruso Department of Otolaryngology - Head and Neck Surgery, Keck Medicine of the University of Southern California, Los Angeles, California, USA.
- Keck School of Medicine of USC, Los Angeles, California, USA.
ORCID-Profile: Roger W Boles, Karla O'Dell
Zitieren
APA
Boles, R. W., Kim, W., Zeng, W., Franco, A., Yang, T., & O'Dell, K. (2026). Randomized Crossover Comparison of the Airway‐Exchange Broncholaryngoscope and Aintree Catheter. The Laryngoscope. https://doi.org/10.1002/lary.70006
Vancouver
Boles RW, Kim W, Zeng W, Franco A, Yang T, O'Dell K. Randomized Crossover Comparison of the Airway‐Exchange Broncholaryngoscope and Aintree Catheter. The Laryngoscope. 2026. doi:10.1002/lary.70006
BibTeX
@article{Boles2026,
author = {Boles, Roger W and Kim, Wihan and Zeng, William and Franco, Antonio and Yang, Tingyu and O'Dell, Karla},
title = {Randomized Crossover Comparison of the Airway‐Exchange Broncholaryngoscope and Aintree Catheter},
journal = {The Laryngoscope},
year = {2026},
doi = {10.1002/lary.70006}
}
EUVIMED