EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of Voxel Grid Size and Statistical Uncertainty on Surface Depth Dose Via Various Planning Techniques and Immobilization Devices Using Monte Carlo Algorithm

Srinivas Challapalli iD, Anupam Choudhary iD, Jyothi Nagesh iD, Shambhavi C, Shirley Lewis iD, Umesh Velu iD, Jayashree Np, Ankita Mehta, Manoj Belwal, Dilson Lobo, Sarath S Nair iD

Technology in Cancer Research & Treatment · 2026-03 · 25

DOI: 10.1177/15330338261425904 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology in Cancer Research & Treatment, online erschienen am 20.03.2026. Verfasst von Srinivas Challapalli und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka India. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This study aims to analyze the impact of the surface dose at depth (1-5mm) in different planning techniques and immobilization devices by varying the dose-voxel size (DVS) and statistical uncertainty (SU) using Monte Carlo (MC) algorithm.

Methods

Three Sets of computed tomography (CT) images were taken from an in-house developed chest phantom, which included an open phantom, a vaclok and a thermoplastic mask. The image sets were pushed to the Monaco planning station for registration and contouring. Six beams of 6 MV photon energy are used to plan an Intensity modulated radiotherapy (IMRT) technique, and a half arc beam is used for Volumetric Modulated arc therapy (VMAT). In each plan, recalculation is performed by changing only the grid size from 1 mm to 8 mm and the statistical uncertainty from 1% to 5% from the parameter control window, keeping the other dose constraints the same. A total of 240 plans were performed for all three image sets together for both the IMRT and VMAT techniques, and the dose at depth was compared and statistically analyzed via the Kruskal–Walli's test.

Results

The homogeneity index (HI), conformity index (CI), and V95% target are increased in both IMRT and VMAT, whereas the SU and DVS are reduced.

Conclusion

Higher statistical uncertainty and grid size significantly reduced dose calculation time, independent of technique or device. surface dose at depth (1-5mm) decreased with increasing grid size and increased with lower statistical uncertainty. IMRT consistently showed higher skin doses than VMAT across all devices, with vac-lock immobilization yielding the highest surface dose in both techniques. These findings show that the surface dose is influenced by beam selection, parameter settings, and the optimization time allocated during treatment planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-ModulatedMonte Carlo MethodAlgorithmsRadiotherapy DosageHumansPhantoms, ImagingTomography, X-Ray ComputedUncertainty

Stichwörter der Autor:innen

dose voxel sizeintensity modulated radiation therapymonte carlostatistical uncertaintyvolumetric arc therapy (VMAT)

Autor:innen und Institutionen

  • Department of Radiation Oncology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka India.
  • Department of Urology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India.
  • Department of Radiation Oncology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India.
  • Medical Physics programme, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Welcomgroup Graduate School of Hotel Administration, Manipal Academy of Higher Education, Manipal, Karnataka, India.

ORCID-Profile: Srinivas Challapalli, Anupam Choudhary, Jyothi Nagesh, Shirley Lewis, Umesh Velu, Sarath S Nair

Zitieren

APA

Challapalli, S., Choudhary, A., Nagesh, J., C, S., Lewis, S., Velu, U., Np, J., Mehta, A., Belwal, M., Lobo, D., & Nair, S. S. (2026). Impact of Voxel Grid Size and Statistical Uncertainty on Surface Depth Dose Via Various Planning Techniques and Immobilization Devices Using Monte Carlo Algorithm. Technology in Cancer Research & Treatment, 25. https://doi.org/10.1177/15330338261425904

Vancouver

Challapalli S, Choudhary A, Nagesh J, C S, Lewis S, Velu U, et al. Impact of Voxel Grid Size and Statistical Uncertainty on Surface Depth Dose Via Various Planning Techniques and Immobilization Devices Using Monte Carlo Algorithm. Technology in Cancer Research & Treatment. 2026;25. doi:10.1177/15330338261425904

BibTeX
@article{Challapalli2026,
  author = {Challapalli, Srinivas and Choudhary, Anupam and Nagesh, Jyothi and C, Shambhavi and Lewis, Shirley and Velu, Umesh and Np, Jayashree and Mehta, Ankita and Belwal, Manoj and Lobo, Dilson and Nair, Sarath S},
  title = {Impact of Voxel Grid Size and Statistical Uncertainty on Surface Depth Dose Via Various Planning Techniques and Immobilization Devices Using Monte Carlo Algorithm},
  journal = {Technology in Cancer Research & Treatment},
  year = {2026},
  volume = {25},
  doi = {10.1177/15330338261425904}
}
Kostenlos starten →