EUVIMEDEUVIMED entdecken
Crossref

The impact of arterial catheter-to-vessel ratio on distal arterial flow and measured arterial pressures in a pulsatile arterial vessel phantom

Mark D Weber iD, Kumaran Senthil, Jeremy C Zuckerberg, Silas T Weber, Adam S Himebauch, Thomas W Conlon

The Journal of Vascular Access · 2025

DOI: 10.1177/11297298251383359 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Vascular Access, 2025. Verfasst von Mark D Weber und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, USA. Hauptthemen laut MEDLINE: Pulsatile Flow, Arterial Pressure, Catheterization, Peripheral, Vascular Access Devices. Die Arbeit nennt 20 Literaturangaben. Gefördert von: National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The effect of catheter size on distal arterial flow and measured arterial pressure remains underexplored. This study evaluates the relationship between catheter-to-vessel ratio (CVR), distal arterial flow, and measured blood pressures in a controlled pulsatile arterial vessel phantom.

Methods

Using in vitro data simulating arterial conditions, distal peak systolic velocity, systolic (SBP), and diastolic (DBP) were analyzed across varying catheter sizes and vessel diameters. Pearson correlation and linear regression were used to assess the relationship between CVR and changes in relative distal velocity, SBP, and DBP.

Results

Relative distal peak systolic velocity exhibited a strong inverse relationship with CVR ( r = −0.903, p < 0.001), with linear regression indicating that for every 10% increase in CVR, distal peak systolic velocity decreased by approximately 9.3%. Flow reduced >20% when CVR exceeded 0.6 and 10 mmHg when CVR exceeded 0.6 and

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulsatile FlowArterial PressureCatheterization, PeripheralVascular Access DevicesPhantoms, ImagingArteriesBlood Pressure DeterminationCatheters, IndwellingModels, CardiovascularBlood Flow VelocityEquipment DesignHumansPredictive Value of TestsRegional Blood FlowLinear ModelsModels, Anatomic

Stichwörter der Autor:innen

Catheterizationcritical careharm reductionmonitoringperipheral/arterialphysiologicthrombosis

Autor:innen und Institutionen

  • Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, USA.
  • Department of Advanced Clinical Practice, Children's Hospital of Philadelphia, Philadelphia, PA, USA.
  • Department of Anesthesiology and Critical Care Medicine, Perelman School of Medicine at the University of Pennsylvania, Children's Hospital of Philadelphia, Philadelphia, PA, USA.
  • Central Bucks School District, Doylestown, PA, USA.

ORCID-Profile: Mark D Weber

Förderung

  • National Institutes of Health

Zitieren

APA

Weber, M. D., Senthil, K., Zuckerberg, J. C., Weber, S. T., Himebauch, A. S., & Conlon, T. W. (2025). The impact of arterial catheter-to-vessel ratio on distal arterial flow and measured arterial pressures in a pulsatile arterial vessel phantom. The Journal of Vascular Access. https://doi.org/10.1177/11297298251383359

Vancouver

Weber MD, Senthil K, Zuckerberg JC, Weber ST, Himebauch AS, Conlon TW. The impact of arterial catheter-to-vessel ratio on distal arterial flow and measured arterial pressures in a pulsatile arterial vessel phantom. The Journal of Vascular Access. 2025. doi:10.1177/11297298251383359

BibTeX
@article{Weber2025,
  author = {Weber, Mark D and Senthil, Kumaran and Zuckerberg, Jeremy C and Weber, Silas T and Himebauch, Adam S and Conlon, Thomas W},
  title = {The impact of arterial catheter-to-vessel ratio on distal arterial flow and measured arterial pressures in a pulsatile arterial vessel phantom},
  journal = {The Journal of Vascular Access},
  year = {2025},
  doi = {10.1177/11297298251383359}
}
Kostenlos starten →